INSTALLATION INSTRUCTIONS
POWER INSTALLATION
If the machine does not have a Plug on the end of the Main power cord, a PLUG or CONNECTOR that
complies to the local laws and regulations should be installed by a qualified electrician. The plug is
classified as a Catagory 0 Main Disconnect. Do not wire this machine directly to a power source without
a plug or connector unless a device that meets this Catagory 0 Main Disconnect requirement is used to
provide power to the machine.
IMPORTANT GROUNDING INSTRUCTIONS
In case of a malfunction of breakdown, grounding reduces the risk of electrical shock by providing a path
of least resistance for electrical current.
This Grinder has an electrical cord with an equipment grounding conductor and a grounding plug. The
plug must be plugged into a matching outlet that is properly installed and grounded according to all local
or other appropriate electrical codes and ordinances.
Before plugging in the Grinder, make sure it will be connected to a supply circuit protected by a
properly-sized circuit breaker or fuse. SEE SERIAL NUMBER PLATE FOR FULL LOAD AMP RATING OF YOUR
MACHINE.
Never modify the plug provided with the machine--if it won't fit the outlet, have a proper outlet and
circuit installed by a qualified electrician.
ALWAYS PROVIDE A PROPER ELECTRICAL GROUND FOR YOUR MACHINE. AN IMPROPER
CONNECTION CAN CAUSE A DANGEROUS ELECTRICAL SHOCK. IF YOU ARE UNSURE OF THE
PROPER ELECTRICAL GROUNDING PROCEDURE, CONTACT A QUALIFIED ELECTRICIAN.
IT IS RECOMMENDED THAT GRINDER HAS ITS OWN PERMANENT POWER CONNECTION FROM
THE POWER DISTRIBUTION PANEL, WITH NO OTHER MAJOR POWER DRAW
EQUIPMENT ON THE SAME LINE.
THE GRINDER IS EQUIPPED WITH A HIGH-LOW VOLTAGE RELAY WHICH IS FACTORY PRESET
AT 100-140 VAC. IF THE POWER SUPPLY LINE DOES NOT DELIVER 100-140 VAC POWER UNDER
LOAD, THE RELAY WILL OPEN AND TRIP OUT THE STARTER.
IF THIS OCCURS, YOUR POWER SUPPLY LINE IS INCORRECT AND MUST BE CORRECTED
BEFORE PROCEEDING FURTHER WITH THE GRINDER. IF THE OPTIONAL TRANSFORMER IS
INSTALLED ON THE OUTSIDE OF THE MACHINE, THE POWER DELIVERED TO THE MACHINE
WILL BE 220VAC, BUT THE POWER IN THE MACHINE MUST BE 100-140VAC UNDER LOAD AS
STATED ABOVE.
DO NOT OPERATE THIS GRINDER WITH AN EXTENSION CORD.
DO NOT OPERATE THIS GRINDER ON A GROUND FAULT INTERUPTER (GFI) CIRCUIT,
NUISANCE TRIPPING OF THE (GFI) MAY OCCUR.
PROPER GROUNDING OF THE RECEPTACLE GROUND IN YOUR BUILDING MUST BE VERIFIED.
IMPROPER GROUNDING IN YOUR BUILDING MAY CAUSE THE GRINDER TO
MALFUNCTION.