BUS BODY ELECTRONICS

2.6 Reheat (HVAC version only)

Note
The reheat mode can only be activated in the AUTO
mode (when the engine is running) and at at least 8°C
outside temperature.
After 10 minutes the reheat mode is terminated automat-
ically.

2.6.1 Activate

Press button (Fig. 5, No.9).
➔ The button's LED lights up and the heating icon ap-
pears on the screen (Fig.25).

2.6.2 Terminate

Press button.
➔ The button's LED turns off and the heating icon disap-
pears on the screen (Fig.19).

2.7 Errors

Note
If an error occurred, the error icon (Fig.6, F) appears on
the display. You can see which kinds of error exist in the
error code table in the section „Error description".

2.7.1 Error display

Wenn ein Systemfehler vorhanden ist, blinkt das Warnsymbol
für die Fehlermeldung in der Anzeige (Figure 26).

2.7.2 Error read out

2.7.2.1 Activate
Press button (Fig.5, No.1) at driver's workplace for 2 sec-
onds until "E1:XY" appears on the display.
➔ The menu for system fault analysis opens.

Figure 24 - SC1000 Entfeuchten aktiv