BUS BODY ELECTRONICS
➔ The count (Fig.27) shows the current frequency of oc-
currence of the error.
2.7.2.2 Error messages
Press buttons to scroll through error messages.
2.7.2.3 Terminate
Press button (Fig.5, No.1) at the drivers's seat until the standard screen appears.
Note
If it is a currently existing error, this is indicated by a dot
between the third and fourth digit of the error code on the
display (Fig.26). If the error is corrected, the point dis-
appears and the count increases.
2.7.2.4 Erase error
Press the button 6 seconds .
➔ The error stops being displayed.
➔ If the error has not been corrected, it appears again with
a dot between the third and fourth digit of the error code
within the error messages (Fig.28).
Note
Servo/ Motor 0 -> Floor water valve
Servo/ Motor 1 -> Foot area flap
Servo/ Motor 2 -> Wind screen flap
Servo/ Motor 3 -> Fresh air flap
2.7.3
Error message overview
Error message dis-
played
00
01
02
Description
No error message
Hot water valve fail-
ure in the frontbox
The air distribution
flap
actuator
(foot
area) of the frontbox
has failed
Figure 26 - SC1000 Error read out
Figure 27 - SC1000 Current Error
Cause/remedy
-
1. Check plug connections
- Electrical and visual check of all
plug connections
2. Replace component
3. Replace control unit
19