4-8 Fan Calibration

After replacing main board or the F-type Fan and upgrading
the firmware, please follow steps as below:
1. Hold on "Menu" button and plug in the power cord.
2. The "Power LED" will flash blue about 2s and release the
"Menu" button at the same time.
3. The "Power LED" light blue, and the projector will power
on. After the logo disappeared, the message
"Fan Information" will be shown on the screen
(as picture "A" shown).
4. After 70 seconds,Please check value.
Note:
- If the Factory Fan RPM Value doesn't meet the above
range,please repeat the step again.
- Make sure the value of "Factory RPM" is 2080~3860.