Run In Test - Eiki EIP-WSS3100 Service Manual

Hide thumbs Also See for EIP-WSS3100:
Table of Contents

Advertisement

4-4 Run In Test

- Temperature: 15°C~35°C
- Circumstance brightness: Normal environment
- Screen size: No concern
- Display mode: ECO mode
After repairing each unit, a Ru
Symptom
Normal repair
NFF
Auto shutdown
- Get into Burn-In Mode
* Cycle setting is based on the defect symptoms. ie: If it is NFF, the run-in time is 4 hours. You have
to set the lamp on for 50 min. and lamp off for 10 min for 4 cycles.
Press power > Left > Right > Menu buttons sequentially to get into service mode
Choose Burn-In Test > enter
Lamp On
Lamp Off
Set burn in cycle
After setting up the time, choose "Get into Burn-In Mode" and press enter
n-in test is necessary (refer to the below table).
Run-in Time
2 hours
4 hours
6 hours
Press right key to adjust the time (50)
Press right key to adjust the time (10)
Press right key to adjust the cycle
Confidential
4-10