Chapter 4
Function Test & Alignment Procedure

4-1 Test Equipment Needed

- PC with HDTV resolution
- DVD player with Multi-system, equipped "Composite", "S-Video"
- HDTV Source (720P,1080P,1080i)
- CL100
- Quantum Data 802BT or CHROMA2327 (Color Video Signal & Pattern Generator)

4-2 Test Condition

- Circumstance brightness: Dark room less than 2 lux.
- Product must be warmed up for 5 minutes.
- Screen size: 87.2 inches diagonal
Zone Definition
< Figure: Zone A(as green line) Definition >
Confidential