2.3. Standard operating modes

4 standard operating modes are available on your air handling unit. Each operating mode has preset air volume and
desired temperature values:
Vėdinimo intensyvumas
Ventilation
intensity
Set
temperature
These settings may be changed (see "Control and Settings").

2.4. Special operating modes

4 special operating modes are available on your air handling unit. During activation, KITCHEN, FIREPLACE and OVERRIDE
modes are set for operation from 1 min. to 300 min. In HOLIDAY mode, operation time is set from 1 to 90 days or for a specific
date. KITCHEN, FIREPLACE and OVERRIDE modes may also be activated by short-cutting designated terminals on the main
board, i.e. by connecting a switch, cooker hood or a motion sensor (see "Installation Manual"). Each operating mode has
preset air volume and desired temperature values:
Tiekiamo oro intensyvumas
Intensity
Ištraukiamo oro intensyvumas
of supplied air
Pageidaujama temperatūra
Intensity
of extract air
Set
temperature
These settings may be changed (see "Control and Settings").

2.5. ECO mode

ECO – an energy saving mode intended for minimizing power consumption. Power consumption is reduced by turning
off heating/cooling devices, making maximum use of outdoor air or decreasing fan speed. During ECO mode:
Electrical heater is blocked, all other external air heating/cooling devices are switched off.
Rooms are cooled/heated with the outside air without a recuperator when the outside air temperature falls within the
set temperature range.
When supply air temperature is below a set minimum value (in winter) or exceeds a maximum value (in summer), the unit
attempts to maintain the air temperature by decreasing ventilation intensity.
Setting the temperature range, switching off recuperation or heating/cooling devices may be done in the ECO mode
settings (see chapter "Control and Settings").
UAB KOMFOVENT we reserve the right to make changes without prior notice
C6M_GUIDE2-19-04
MINIMALUS
AWAY
Vėdinimo intensyvumas
20%
Pageidaujama
20%
temperatūra
20°C
20°C
ŽIDINYS
VIRTUVĖ
KITCHEN
FIREPLACE
Tiekiamo oro intensyvumas
80%
60%
80%
60%
Ištraukiamo oro intensyvumas
20%
50%
Pageidaujama temperatūra
20°C
20°C
20%
50%
20°C
20°C
NORMALUS
NORMAL
Vėdinimo intensyvumas
50%
Pageidaujama
50%
temperatūra
20°C
20°C
PIRMENYBĖ
OVERRIDE
Tiekiamo oro intensyvumas
80%
80%
Ištraukiamo oro intensyvumas
80%
Pageidaujama temperatūra
20°C
80%
20°C
INTENSYVUS
INTENSIVE
Vėdinimo intensyvumas
70%
Pageidaujama
70%
temperatūra
20°C
20°C
ATOSTOGOS
HOLIDAYS
Vėdinimo įrenginys kelis
kartus per dieną įsijungs
Ventilation unit will turn on for 30 min-
30-čiai minučių. Kitu laiku
utes several times a day. At other times,
vėdinimas bus išjungtas.
Vėdinimo intensyvumas
the ventilation unit is switched off.
20%
Ventilation intensity 20%.
Pageidaujama temperatūra
20°C
20°C
MAKSIMALUS
BOOST
100%
Pageidaujama
100%
temperatūra
20°C
20°C