Example
# Set the rate limit of port eth2 to 50%.
[root@localhost tool]# hinicadm rate -i eth2 -l 50
Set eth2 tx limit rate to 50% succeed
# Query the rate limit of port eth2.
[root@localhost tool]# hinicadm rate -i eth2
eth2 tx limit rate: 50%.
eth2 default tx limit rate: 100%.

6.1.4.10 Querying the Chip and Optical Module Temperatures (temperature)

Function
The temperature command is used to query and set the chip and optical module temperatures
of a specified IN200.
Format
hinicadm temperature -i <devicename>
Parameters
Parameter
devicename
Usage Instruction
None
Example
# Query the chip and optical module temperatures of the IN200.
[root@localhost tool]# hinicadm temperature -i hinic0
current temperature (unit: degree centigrade)
controller: 55
sfp1: 59
sfp2: absent
sfp3: NA
sfp4: 56
Issue 06 (2019-07-27)
If the command contains -d, the setting is permanent and takes effect after a restart.
If the command does not contain -d, the setting is not permanent and will be restored to
the factory setting after a restart.
Copyright © Huawei Technologies Co., Ltd.
Description
Indicates the name of the
IN200 to be queried in the
system.