EMBEDDED
18. Double-click on Slot 0 or press Set board/equipment button
(BL2500 Digital Inputs) and press OK button. The bl25di I/O board is placed in Slot 0. Double-click on
Channel 1. On the Connect I/O channel window press Connect button several times until all the free
variables are connected. Press Close button.
19. Double-click on Slot 1 and select bl25led (BL2500 on-board LEDs) board. Double-click on Channel 1
and connect the free variable LED1. Press Close button.
20. Double-click on Slot 2 and select bl25ai (BL2500 Analog Input) board. Double-click on Channel 1 and
connect the AD0 variable. Press Close button.
21. Double-click on Slot 3 and select bl25ao (BL2500 Analog Output) board. Double-click on Channel 1
and connect the DA1 variable. Press Close button. Select File menu → Save (or press Save button
on the toolbar) to save the I/O connection. Close the I/O connection window.
22. Before downloading the PLC application to the Target PLC, the application needs to be compiled. On
the B25TEST1 – Programs window, select Make menu → Compiler Options to check that
RABBIT: TIC code for Rabbit-based controllers is selected. Press OK button.
If RABBIT target is not selected, click on RABBIT target and press Select button. Alternatively you
can double-click on RABBIT target.
OEM Technology Solutions
Running Sample Applications
on the toolbar. Select bl25di board
Page 23