OEM BL2500 User Manual page 22

Embedded plc z-world single board computer
Table of Contents

Advertisement

PLC BL2500 User's Manual
EMBEDDED
2. Double-click on the sample application (for example, rfdemo) to open the Programs Manager
window.
3. On the Programs Manager window, select Debug → Simulate (or press Simulate button
the toolbar). The Debugger, I/O simulation and Debug program windows are displayed.
4. The I/O simulation window shows the I/O boards used by the application (Boards 0 to 4). Board 0
(column 0) has 8 digital inputs; Board 1 (column 1) has 8 analog inputs; Board 2 (column 2) has 8
message (strings) outputs; Board 3 (column 3) has 8 digital outputs and Board 4 (column 4) has 8
analog outputs. On Board 0 (column 0) click on Input 1 and Input 4, a message start and Lead are
displayed in message outputs 4 and 5 respectively; and Board 3 will show the LED outputs being
turned ON in sequence. On the Debug programs window the Drive and Lead programs change to
active state. Unset the digital input 4 and set any of the digital inputs 5 (Flash) or 6 (Random).
5. To close the simulation of the application, close the Debugger window. Close the Programs window.
6. Try with other sample applications such as the one listed in the introduction of this chapter. All the
sample applications can run in simulation mode.