EMBEDDED

3.3.2 Downloading and running the ISaGRAF application

Use the following procedure to download a sample application (b25qld) to the BL2500 Target that uses
physical I/Os. The Target PLC must be running a licensed
connected to 4 digital inputs (use the procedure above to create an I/O connector). It also assumes that
the Target is connected to the PC either via Ethernet or serial port.
1. Open the ISaGRAF Project Management by double-clicking on the ISaGRAF Projects icon on your
Desktop or selecting Start menu → Programs → ISaGRAF 3.5 → Projects. On the Projects
Management window, double-click on the b25qld project.
2. Select Debug → Link setup (or press Link Setup) and configure the Target PLC ↔ PC link. Follow
the guidelines on Step 2 of the previous section.
3. Select Debug → Debug (or press Debug) to open the Debugger window. If an application is
running, stop it (press Stop button
Download to download the b25qld application to the target. A progress bar on the Debugger window
shows the progress of the download process. Once the downloading is completed the application
starts running and the following SpotLight window is displayed.
4. The Digital inputs IN00 and IN01 of the BL2500 are wired as the Left and Right switches on the
b25qld application. The BL2500 on-board LED DS3 is the output of the light. The BL2500 digital
inputs IN02 and IN03 move the window's screen to the left and right respectively.
5. To check the I/O connections, close the Debugger window and on the B25QLD – Programs window
select Project → I/O connection. Check the wiring of the channels.