7.12.2 Creating the equipotential bonding
The earthing cable conducts away any static charging to ground.
Fig. 51: Creating the equipotential bonding
(1) - Connection point of the machine
base plate
To create the equipotential bonding:
1.
Secure the earthing cable (2) to the connection point on the
control (3).
2.
Guide the earthing cable (2) upwards to the machine.
3.
Secure the earthing cable (2) with screw and tab connector
to the connection point on the machine base plate (1).
(2) - Earthing cable
(3) - Connection point on the control