Gs1 Databar Omnidirectional; Gs1 Databar Truncated; Gs1 Databar Limited; Gs1 Databar Expanded - Star StarPRNT SM-L Series Command Specifications

Line thermal printer
Table of Contents

Advertisement

4.1.8.

GS1 Databar Omnidirectional

Sends 13 digits of data except for AI (application identifiers) and check digits.
AI ("01") is added automatically.
One check digit is added automatically.
When HRI printing is enabled, 18 digits of ["(01)", (d1...d13), check digit] are printed by the HRI.
When the setting for the bar code height is smaller than [module width x33], the bar code height is printed at the
[module width x33]. (Except for HRI heights)
4.1.9.

GS1 Databar Truncated

Sends 13 digits of data except for AI (application identifiers) and check digits.
AI ("01") is added automatically.
One check digit is added automatically.
When HRI printing is enabled, 18 digits of ["(01)", (d1...d13), check digit] are printed by the HRI.
When the setting for the bar code height is smaller than [module width x13], the bar code height is printed at the
[module width x13]. (Except for HRI heights)

4.1.10. GS1 Databar Limited

Sends 13 digits of data except for AI (application identifiers) and check digits.
When HRI printing is enabled, 18 digits of ["(01)", (d1...d13), check digit] are printed by the HRI.
When the setting for the bar code height is smaller than [module width x10], the bar code height is printed at the
[module width x10]. (Except for HRI heights)

4.1.11. GS1 Databar Expanded

When sending special characters (FNC1) or "(",")", the following double-byte data is sent.
Data
FNC1
(
)
The special character ("(",")") is processed as shown in the following table.
Special characters
character
Hex.
(
28
)
29
When HRI character printing is enabled, special characters are handled in the HRI as shown below.
Control characters (FNC1) are not printed.
Special characters ("(",")") are printed.
Bar code data ["{" + ("(", ")")] is printed as ("(", ")").
When the setting for the bar code height is smaller than [module width x34], the bar code height is printed at the
[module width x34]. (Except for HRI heights)
Star PRNT Command Specifications
Send data
ASCII
{ + 1
{ + (
{ + )
Decimal
40
"(" is entered in the HRI character. AI can be highlighted by using in
combination with ")". ") " is not encoded.
41
The first ")" after d1 is handled as an AI and the data divider.
")" is entered in the HRI character. ") " is not encoded.
Hex.
7B + 31
7B + 28
7B + 29
4-9
Decimal
123 + 49
123 + 40
123 + 41

Hide quick links: