Start-up
necting terminals 1 and 2 to the motor as follows
(see fig. 2):
-
-
Connect the phase conductor to connecting ter-
minal L (E) (see fig. 2).
Connect the neutral conductor to connecting
terminal N (F) (see fig. 2).
Connect an external shutter push-button to con-
necting terminal S1 and S2 (see fig. 2):
-
-
Connect the neutral conductor of the motor to
the neutral conductor of the house installation.
Connect the phase connection of the shutter
push-button with the phase conductor of the
house installation.
Fix the actuator to an appropriate flush-mounting
box. If required, you can remove the fixing lug (B).
Close the flush-mounting box using an appropri-
ate cover.
Switch the fuse of the power circuit on again to
activate the teach-in mode of the device (see „5.3
Teaching-in" on page 34).
5.2.2

Surface-mounting box installation

To install the shutter actuator in a surface-mounting box,
please proceed as follows:
32
Connecting terminal 2 (C): "Up"
Connecting terminal 1 (D): "Down"
Connecting terminal S1 (G): "Down"
Connecting terminal S2 (H): "Up"