Technical specifications

11
Technical specifications
Device short description:
Supply voltage:
Current consumption:
Power consumption in standby: 0.2 W
Max. switching capacity:
Load type:
Relay:
Cable type and cross section: rigid and flexible cable,
Installation:
Degree of protection:
Protection class:
Ambient temperature:
Dimensions (W x H x D):
Weight:
Radio frequency band:
Maximum radiated power:
Receiver category:
Typ. open area RF range:
Duty cycle:
42
HmIP-FROLL
230 V/50 Hz
2.2 A max.
500 VA
motor load
1x NO contact, 1x change-
over contact
0.75-1.5 mm²
only in switch boxes (device
boxes) in accordance with
DIN 49073-1 or junction
boxes (surface-mounting
boxes) in accordance with
DIN 60670-1
IP20
II
-10 to +55 °C
54 x 33 x 41 mm
40 g
868.0-868.6 MHz
869.4-868.65 MHz
10 dBm
SRD category 2
180 m
< 1 % per h/< 10 % per h