INSTRUCTION MANUAL
Model HC
2.1.3.1
2.1.3.2
Reference 219
Page 30 of 46
Replacement / Disposal of Desiccant (continued)
Remove plug from the desiccant fill (ON SMALL TOWERS
WITH THREADED DESICCANT FILLS).
The tower can be blown clean with an air hose or may be
washed out with a water hose, if desired, but time must be
allowed if this is done to completely dry the tower before
refilling it with desiccant.
Replace drain plug in bottom of the tower.
Refill the chamber with the specified desiccant. Refer to the
Specifications in Section 5 for required desiccant quantity.
Do not tamp the desiccant.
Replace the manway cover components or the pipe plug
and tighten.
Repeat process for the other tower.
Make sure all drain and fill ports are in place and properly
tightened. Soap test for leaks before returning the dryer to
service.
Slowly repressurize the dryer and turn on.
For HC dryers with a mixed desiccant bed
If a mixed bed with molecular sieve is required, the
activated alumina should be installed on the bottom of the
drying bed with the molecular sieve on the top.
Reference Section 7 for the Material Safety Data Sheet (MSDS).
Rev 2
06/20/2013