Sign In
Upload
Download
Table of Contents
Contents
Add to my manuals
Delete from my manuals
Share
URL of this page:
HTML Link:
Bookmark this page
Add
Manual will be automatically added to "My Manuals"
Print this page
×
Bookmark added
×
Added to my manuals
Manuals
Brands
Keysight Technologies Manuals
Multimeter
U1461A
User manual
Changing The Insulation Resistance Test Voltage; Table 2-1 Rotary Switch Position For Insulation Resistance Tests .52 Table 2-2 User Test Voltage Range For Insulation Resistance - Keysight Technologies U1461A User Manual
Insulation multimeter/insulation tester
Hide thumbs
Also See for U1461A
:
Service manual
(59 pages)
,
Service manual
(64 pages)
1
2
3
4
5
6
7
8
9
10
Table Of Contents
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
page
of
163
Go
/
163
Contents
Table of Contents
Bookmarks
Table of Contents
Advertisement
2
Making Measurements
Changing the insulation resistance test voltage
You can adjust the test voltage value of each test voltage position (see
from the Setup menu
Table 2-2
the insulation resistance test voltage"
Table 2-2
User test voltage range for insulation resistance
Rotary switch
position
[a] Minimum increment of 1 V between each subsequent value.
66
(Menu
lists the available range for each test voltage position. See
Parameter
IR: 50 V
IR: 100 V
IR: 250 V
IR: 500 V
IR: 1000 V
8).
on page 149 for more information.
F(actory) defaul t
50 V
100 V
250 V
500 V
1000 V
"Changing
Range
Available U(ser) range
10 V to 60 V
10 V to 120 V
10 V to 300 V
10 V to 600 V
10 V to 1100 V
U1461A/U1453A User's Guide
Table
2-1)
[a]
Table of
Contents
Previous
Page
Next
Page
1
...
63
64
65
66
67
68
69
70
Advertisement
Table of Contents
Related Manuals for Keysight Technologies U1461A
Multimeter Keysight Technologies U1450 Series Service Manual
Insulation testers and insulation multimeter (64 pages)
Test Equipment Keysight Technologies U1453A Service Manual
Insulation testers and insulation multimeter, u1450 series (59 pages)
Multimeter Keysight Technologies U1253B Quick Start Manual
Handheld digital true rms oled multimeter (194 pages)
Multimeter Keysight Technologies U1253B User's And Service Manual
True rms oled multimeter (205 pages)
Multimeter Keysight Technologies U3401A Quick Start Manual
4 1/2 digit dual display multimeter (84 pages)
Multimeter Keysight Technologies U1273A User Manual
Handheld digital multimeter (161 pages)
Multimeter Keysight Technologies U1273A Quick Start Manual
Handheld digital multimeter (25 pages)
Multimeter Keysight Technologies U1231A Service Manual
Handheld digital multimeter (55 pages)
Multimeter Keysight Technologies U1281A Programming Manual
Handheld digital multimeter (29 pages)
Multimeter Keysight Technologies U1282A Modification Recommended Service Note
Handheld digit multimeter (3 pages)
Multimeter Keysight Technologies U2741A User Manual
Usb modular 5.5 digits digital multimeter (63 pages)
Multimeter Keysight Technologies U2741A Service Manual
Usb modular 5.5 digits digital multimeter (45 pages)
Multimeter Keysight Technologies U1252B Modification Recommended Service Note
Handheld digit multimeter (3 pages)
Multimeter Keysight Technologies U1251B Quick Start Manual
Handheld digital multimeter (178 pages)
Multimeter Keysight Technologies U1251B Modification Recommended Service Note
Handheld digit multimeter (3 pages)
Multimeter Keysight Technologies U1241C Datasheet
Handheld digital multimeters (15 pages)
Related Content for Keysight Technologies U1461A
U2741A Ac Voltage Verification Test
Keysight Technologies U2741A
U1281A Removing Test Lead Resistance
Keysight Technologies U1281A
EDU34450A Removing Test Lead Resistance Errors
Keysight Technologies EDU34450A
EDU34450A Ac Voltage Verification Test
Keysight Technologies EDU34450A
U1273A Resistance Measurements
Keysight Technologies U1273A
U1251B Performing Resistance, Conductance, And Continuity Measurements
Keysight Technologies U1251B
U1450 Series Non-Contact Voltage (Ncv) Calibration
Keysight Technologies U1450 Series
8163A Calibrating Test Setups That Use An 81570A/71A/73A/78A
Keysight Technologies 8163A
34450A Configure[:Primary]:Resistance
Keysight Technologies 34450A
U2741A Measuring Resistance
Keysight Technologies U2741A
U1253B Measuring Resistance, Conductance, And Testing Continuity
Keysight Technologies U1253B
U1231A Recommended Test Equipment
Keysight Technologies U1231A
U1273A Measuring Resistance
Keysight Technologies U1273A
34450A Connecting Test Leads To The Terminals
Keysight Technologies 34450A
34450A Measuring Resistance
Keysight Technologies 34450A
U1253B Performing Resistance, Conductance, And Continuity Measurements
Keysight Technologies U1253B
This manual is also suitable for:
U1453a
Table of Contents
Print
Rename the bookmark
Delete bookmark?
Delete from my manuals?
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL