Sign In
Upload
Manuals
Brands
Keysight Technologies Manuals
Multimeter
U1273A
User Manuals: Keysight Technologies U1273A Multimeter
Manuals and User Guides for Keysight Technologies U1273A Multimeter. We have
3
Keysight Technologies U1273A Multimeter manuals available for free PDF download: Quick Start Manual, User Manual
Keysight Technologies U1273A User Manual (161 pages)
Handheld Digital Multimeter
Brand:
Keysight Technologies
| Category:
Multimeter
| Size: 8 MB
Table of Contents
Safety Symbols
5
Safety Considerations
6
Measurement Category
8
Environmental Conditions
9
Regulatory Markings
10
Waste Electrical and Electronic Equipment (WEEE) Directive 2002/96/ EC
11
Product Category
11
Sales and Technical Support
11
Table of Contents
13
1 Introduction
22
About this Manual
22
Documentation Map
22
Safety Notes
22
Preparing Your Multimeter
23
Check the Shipment
23
Install the Batteries
23
Figure 1-1 Installing the Batteries
24
Figure 1-2 Change Battery Display
25
Turn on Your Multimeter
26
Automatic Power-Off
26
OLED Auto DIM Function
27
Increase the OLED Brightness
27
Select the Range
27
Alerts and Warnings During Measurement
28
Figure 1-3 Input Warning Display (a INPUT)
29
Figure 1-4 Input Warning Display (Ma INPUT)
29
Adjust the Tilt Stand
30
Connect the IR-USB Cable
30
Figure 1-5 Tilt-Stand Adjustment and IR-USB Cable Connection
30
Figure 1-6 Keysight GUI Data Logger Software
31
Power-On Options
32
Table 1-1 Power-On Options
32
Your Multimeter in Brief
33
Dimensions
33
Figure 1-7 Width Dimensions
33
Figure 1-8 Height and Depth Dimensions
34
Overview
35
Figure 1-9 Front Panel
35
Table 1-2 Front Panel Parts
35
Figure 1-10 Rear Panel
36
Table 1-3 Rear Panel Parts
36
Rotary Switch
37
Figure 1-11 U1273A/U1273AX Rotary Switch
37
Table 1-4 U1273A/U1273AX Rotary Switch Functions
38
Keypad
39
Figure 1-12 Keys
39
Table 1-5 Keypad Functions
40
Display Screen
44
Figure 1-13 Display Screen Example (Single Display)
44
Figure 1-14 Display Screen Example (Dual Display)
44
Table 1-6 General Annunciators
45
Figure 2-30 Temperature Measurement Without Ambient
46
Table 1-7 Measurement Units Display
48
Table 1-8 Analog Bar Graph Display
49
Input Terminals
50
Figure 1-15 Connector Terminals
50
Table 1-9 Terminal Connections for Different Measuring
51
Cleaning Your Multimeter
52
2 Making Measurements
54
Crest Factor
54
Measuring AC Voltage
55
Figure 2-1 AC Voltage Display
55
Table 2-1 Rotary Switch Positions Allowing AC Voltage
55
Figure 2-2 Measuring AC Voltage
56
Figure 2-3 AC Voltage with LPF Display
57
Table 2-2 Rotary Switch Positions Allowing AC Voltage Measurements with LPF
57
Using the LPF (Low Pass Filter) Function for AC Measurements
57
Measuring DC Voltage
58
Figure 2-4 DC Voltage Display
58
Table 2-3 Rotary Switch Positions Allowing DC Voltage
58
Figure 2-5 Measuring DC Voltage
60
Figure 2-6 Filter for DC Voltage Measurements
61
Using the Filter Function for DC Measurements
61
Measuring AC and DC Signals
62
Table 2-4 Rotary Switch Positions Allowing AC+DC Signal
62
Figure 2-7 AC+DC Voltage Display
63
Figure 2-8 AC+DC Current Display
63
Using the LPF (Low Pass Filter) Function for AC+DC Measurements
64
Making Db Measurements
64
Figure 2-9 Low Pass Filter(LPF) for AC+DC Voltage Measurements
64
Figure 2-10 Dbm Display
65
Table 2-5 Rotary Switch Positions Allowing Dbm Measurements
65
Table 2-6 Rotary Switch Positions Allowing Dbv Measurements
66
Using ZLOW for Voltage Measurements
67
Figure 2-11 Dbv Display
67
Table 2-7 Rotary Switch Positions Allowing ZLOW Measurements
67
Low
67
Figure 2-12 ZLOW Display
68
Measuring Resistance
69
Table 2-8 Rotary Switch Position Allowing Resistance Measurements
69
Figure 2-13 Resistance Display
70
Figure 2-14 Measuring Resistance
71
Measuring Conductance
72
Testing for Continuity
73
Table 2-9 Rotary Switch Position Allowing Continuity Tests
73
Table 2-10 Threshold Resistance Values
73
Figure 2-15 Continuity Operation
74
Figure 2-16 Testing for Continuity
75
Using Smart Ω for Resistance Measurements
76
Table 2-11 Rotary Switch Position Allowing Smart Ω
76
Figure 2-17 Smart Ω (with Bias Voltage) Display
77
Figure 2-18 Smart Ω (with Leakage Current) Display
77
Figure 2-19 Measuring Leakage Current
78
Testing Diodes
79
Figure 2-20 Diode Display
79
Table 2-12 Rotary Switch Position Allowing Diode Tests
79
Figure 2-21 Open Diode Display
80
Figure 2-22 Testing a Forward-Bias Diode
81
Figure 2-23 Testing a Reverse-Bias Diode
82
Using Auto-Diode for Diode Tests
83
Table 2-13 Rotary Switch Position Allowing Auto-Diode Tests
83
Table 2-14 Auto-Diode Voltage Thresholds
83
Figure 2-24 Auto-Diode Display (GOOD Status)
84
Figure 2-25 Auto-Diode Display (NGOOD Status)
84
Measuring Capacitance
85
Figure 2-26 Capacitance Display
85
Table 2-15 Rotary Switch Position Allowing Capacitance Measurements
85
Figure 2-27 Measuring Capacitance
86
Measuring Temperature
87
Figure 2-28 Temperature Display
87
Figure 2-29 Measuring Surface Temperature
89
Compensation
90
Measuring AC or DC Current
91
Table 2-17 Rotary Switch Positions Allowing Current
91
Figure 2-31 DC Current Display
92
Figure 2-32 Measuring DC Current
94
Figure 2-33 Measuring AC Current
95
Figure 2-34 Current Measurement Setup
96
Figure 2-35 4-20 Ma % Scale Display
97
Scale of 4-20 Ma or 0-20 Ma
97
Table 2-18 Rotary Switch Positions Allowing Current Measurements
97
Table 2-19 % Scale Measurement Range
98
Figure 2-36 Measuring DC Current Using the 0-20 Ma % Scale
99
Measuring Frequency
100
Table 2-20 Rotary Switch Positions Allowing Frequency
100
Figure 2-38 Frequency Display
102
Figure 2-39 Pulse Width Display
103
Measuring Pulse Width
103
Figure 2-40 Duty Cycle Display
104
Measuring Duty Cycle
104
3 Multimeter Features
106
Making Relative Measurements (Null)
106
Figure 3-1 Null Display
106
Multimeter Features
106
Figure 3-2 Null Operation
107
Making Scale Transfers (Scale)
108
Table 3-1 Available Scale Conversions
108
Figure 3-3 Scale Operation
109
Capturing Maximum and Minimum Values (Maxmin)
110
Figure 3-4 Maxmin Display
110
Capturing Peak Values (Peak)
112
Figure 3-5 Peak Display
112
Figure 3-6 Peak Mode Operation
113
Freezing the Display (Trighold and Autohold)
114
Recording Measurement Data (Data Logging)
115
Table 3-2 Data Logging Maximum Capacity
115
Figure 3-7 Manual Log Display
116
Performing Interval Logs (AUTO)
116
Performing Manual Logs (HAND)
116
Figure 3-8 Interval Log Display
117
Performing Event Logs (TRIG)
118
Table 3-3 Event Log Trigger Conditions
118
Figure 3-9 Event Log Display
119
Reviewing Previously Recorded Data (View)
120
Figure 3-10 View Display
120
Figure 3-11 Empty View Display
120
Sanitizing the Log Memories
121
4 Multimeter Setup Options
124
Using the Setup Menu
124
Table 4-1 Setup Menu Key Functions
124
Editing Numerical Values
125
Setup Menu Summary
127
Table 4-2 Setup Menu Item Descriptions
127
Setup Menu Items
132
Changing the Variation Count
132
Changing the Recording Option
132
Changing the Sample Interval Duration
133
Changing the Decibel Display
133
Changing the Custom Dbm Reference Impedance
134
Changing the Thermocouple Type
135
Changing the Temperature Unit
135
Changing the % Scale Range
136
Changing the Continuity Alert
137
Changing the Minimum Measurable Frequency
137
Changing the Beep Frequency
138
Changing the Auto Power-Off (APO) Timer
138
Changing the OLED Behavior
139
Changing the Power-On Melody
139
Changing the Power-On Greetings
140
Changing the Baud Rate
141
Changing the Data Bits
141
Changing the Parity Check
142
Enabling the Echo Feature
142
Enabling the Print Feature
143
Enabling the Overvoltage Alert
143
Changing the User Scale Conversion Value and Unit
144
Enabling Smooth Mode
144
Resetting the Multimeter's Setup Options
145
Changing the Battery Type
146
Enabling the Filter
146
Table 4-3 Filter (LPF) Options
147
Table 4-4 Firmware Version 1.64 or Older
147
Table 4-5 Firmware Version 1.95 or Newer
147
5 Characteristics and Specifications
149
Shift Functions Using the Shift Key
151
Table A-1 U1273A/U1273AX Default and Shift Functions
152
Measurements
155
Table B-1 U1273A/U1273AX Dual Display Combinations
156
Advertisement
Keysight Technologies U1273A Quick Start Manual (219 pages)
Handheld Digital Multimeter
Brand:
Keysight Technologies
| Category:
Measuring Instruments
| Size: 13 MB
Table of Contents
Install the Batteries
4
Turn on the Multimeter
4
Understanding the Rotary Switch
7
Understanding the Keypad
8
Check the Fuse
20
Installation des Batteries
26
Mise Sous Tension du Multimètre
26
Présentation du Pavé Numérique
30
Einlegen der Batterien
48
Einschalten des Multimeters
48
Die Tastatur
52
Installare le Batterie
72
Panoramica Sul Tastierino
76
Instalación de las Pilas
94
Instalar as Pilhas
200
Noções Básicas sobre O Teclado
204
Keysight Technologies U1273A Quick Start Manual (25 pages)
Handheld Digital Multimeter
Brand:
Keysight Technologies
| Category:
Multimeter
| Size: 0 MB
Table of Contents
Table of Contents
3
Install the Batteries
6
Turn on the Multimeter
6
The Multimeter at a Glance
8
Understanding the Rotary Switch
9
Understanding the Keypad
10
Understanding the Input Terminals
11
Performing Measurements and Tests
12
Voltage Measurements
12
Resistance Measurements
15
Continuity Tests
16
Diode Tests
18
Capacitance Measurements
19
Temperature Measurements
20
Current Measurements
21
Check the Fuse
22
Advertisement
Advertisement
Related Products
Keysight Technologies U1273AX
Keysight Technologies U1253B
Keysight Technologies U1233A
Keysight Technologies U1232A
Keysight Technologies U1281A
Keysight Technologies U1282A
Keysight Technologies U1252B
Keysight Technologies U1242C
Keysight Technologies U1241C
Keysight Technologies U1251B
Keysight Technologies Categories
Measuring Instruments
Test Equipment
Control Unit
Portable Generator
Power Supply
More Keysight Technologies Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL