Multimeter
34450A
Keysight Technologies 34450A Manuals
Manuals and User Guides for Keysight Technologies 34450A. We have
3
Keysight Technologies 34450A manuals available for free PDF download: Programmer's Reference Manual, Quick Start Up Manual, User Manual
Keysight Technologies 34450A Programmer's Reference Manual (311 pages)
Digit Multimeter
Brand:
Keysight Technologies
| Category:
Multimeter
| Size: 1.42 MB
Table of Contents
Table of Contents
2
Notices
6
Declarations of Conformity
7
Safety Information
8
34450 A Remote Operation
9
Introduction to the SCPI Language
10
Scpi Parameter Types
12
Keysight 34450A Command Quick Reference
14
Measurement Configuration Commands
19
Triggering Commands
19
Calibration Commands
20
Power-On and Reset State
23
2 SCPI Programming
25
Abort
26
Initiate[:Immediate]
27
Read
28
Unit:temperature
29
Calculate Subsystem Introduction
30
Calculate:state
31
Calculate:function
32
Calculate:limit:lower
34
Calculate:limit:upper
36
Calculate:average:average
38
Calculate:average:count
39
Calculate:average:maximum
40
Calculate:average:minimum
41
Calculate:db:reference
42
Calculate:dbm:reference
44
Calculate:null:offset
46
Calibration Subsystem Introduction
47
Calibration[:All]
48
Calibration:count
49
Calibration:flat
50
Calibration:secure:code
51
Calibration:secure:state
53
Calibration:store
55
Calibration:string
56
Calibration:value
58
Configure Subsystem Introduction
60
Using the Configure Command
61
Configure[:Primary]
62
Configure[:Primary]:Capacitance
63
Configure[:Primary]:Continuity
65
Configure[:Primary]:Current[:DC]
67
Configure[:Primary]:Current:ac
69
Configure[:Primary]:Diode
71
Configure[:Primary]:Frequency
72
Configure[:Primary]:Fresistance
74
Configure[:Primary]:Resistance
76
Configure[:Primary]:Temperature
78
Configure[:Primary][:Voltage][:DC]
80
Configure[:Primary][:Voltage]:Ac
82
Configure:secondary
84
Configure:secondary:current[:DC]
85
Configure:secondary:current:ac
87
Configure:secondary:frequency
89
Configure:secondary[:Voltage][:DC]
91
Configure:secondary[:Voltage]:Ac
93
DATA Subsystem Introduction
96
Data:data? Nvmem
97
Data:delete NVMEM
98
Data:last
99
Data:points? NVMEM
100
Display Subsystem Introduction
101
Display[:Window1][:State]
102
Display:window2[:State]
103
Format Subsystem Introduction
104
Format:output
105
Fetch Subsystem Introduction
107
Fetch
108
IEEE-488 Common Commands Introduction
109
Cls
110
Ese
111
Esr
113
Idn
115
Opc
116
Opc
117
Psc
118
Rcl
120
Rst
121
Sav
122
Sre
123
Stb
125
Trg
127
Tst
128
Wai
129
Measure Subsystem Introduction
130
Measure[:Primary]:Capacitance
132
Measure[:Primary]:Continuity
134
Measure[:Primary]:Current:ac
136
Measure[:Primary]:Current[:DC]
138
Measure[:Primary]:Diode
140
Measure[:Primary]:Frequency
141
Measure[:Primary]:Fresistance
143
Measure[:Primary]:Resistance
145
Measure[:Primary]:Temperature
147
Measure[:Primary][:Voltage][:DC]
149
Measure[:Primary][:Voltage]:Ac
151
Measure:secondary:current:ac
153
Measure:secondary:current[:DC]
155
Measure:secondary:frequency
157
Measure:secondary[:Voltage][:DC]
159
Measure:secondary[:Voltage]:Ac
161
Memory Subsystem Introduction
163
Memory:state:recall:auto
164
Memory:state:store
166
Sample Subsystem Introduction
167
Sample:timer
168
Sense Subsystem Introduction
169
[Sense:][Primary:]Capacitance:range
174
[Sense:][Primary:]Capacitance:range:auto
176
[Sense:][Primary:]Current[:DC]:Range
178
[Sense:][Primary:]Current[:DC]:Range:auto
180
[Sense:][Primary:]Current[:DC]:Resolution
182
[Sense:][Primary:]Current:ac:range
184
[Sense:][Primary:]Current:ac:range:auto
186
[Sense:][Primary:]Current:ac:resolution
188
[Sense:][Primary:]Frequency:voltage:range
190
[Sense:][Primary:]Frequency:voltage:range:auto
192
[Sense:][Primary:]Frequency:aperture
194
[Sense:][Primary:]Frequency:current:range
196
[Sense:][Primary:]Frequency:current:range:auto
198
[Sense:][Primary:]Fresistance:range
200
[Sense:][Primary:]Fresistance:range:auto
202
[Sense:][Primary:]Fresistance:resolution
204
[Sense:][Primary:]Fresistance:ocompensated
206
[Sense:][Primary:]Function
207
[Sense:][Primary:]Resistance:range
209
[Sense:][Primary:]Resistance:range:auto
211
[Sense:][Primary:]Resistance:resolution
213
[Sense:][Primary:]Resistance:ocompensated
215
[Sense:][Primary:]Temperature:transducer:thermistor:type
216
[Sense:][Primary:]Voltage[:DC]:Range:auto
217
[Sense:][Primary:]Voltage[:DC]:Resolution
219
[Sense:][Primary:]Voltage:ac:range
221
[Sense:][Primary:]Voltage:ac:range:auto
223
[Sense:][Primary:]Voltage:ac:resolution
225
[Sense:][Primary:]Voltage[:DC]:Impedance:auto
227
[Sense:][Primary:]Voltage[:DC]:Range
229
[Sense:]Secondary:current[:DC]:Range
231
[Sense:]Secondary:current[:DC]:Range:auto
233
[Sense:]Secondary:current[:DC]:Resolution
235
[Sense:]Secondary:current:ac:range
237
[Sense:]Secondary:current:ac:range:auto
239
[Sense:]Secondary:current:ac:resolution
241
[Sense:]Secondary:frequency:voltage:range
243
[Sense:]Secondary:frequency:voltage:range:auto
245
[Sense:]Secondary:frequency:aperture
247
[Sense:]Secondary:frequency:current:range
248
[Sense:]Secondary:frequency:current:range:auto
250
[Sense:]Secondary:function
252
[Sense:]Secondary:voltage[:DC]:Range:auto
254
[Sense:]Secondary:voltage[:DC]:Resolution
256
[Sense:]Secondary:voltage:ac:range
258
[Sense:]Secondary:voltage:ac:range:auto
260
[Sense:]Secondary:voltage:ac:resolution
262
G[Sense:]Secondary:voltage[:DC]:Impedance:auto
264
[Sense:]Secondary:voltage[:DC]:Range
266
Status Subsystem Introduction
268
Command Summary
269
Status:operation[:Event]
270
Status:operation:condition
272
Status:operation:enable
274
Status:preset
276
Status:questionable[:Event]
277
Status:questionable:condition
279
Status:questionable:enable
281
System Subsystem Introduction
283
System:beeper[:Immediate]
284
System:beeper:state
285
System:communicate:enable
287
System:communicate:gpib[:Self]:Address
288
System:error
290
System:language
292
System:lfrequency
293
System:persona:manufacturer
294
System:persona:manufacturer:default
295
System:preset
296
System:version
297
Trigger Subsystem Introduction
298
Triggering the Multimeter
299
Trigger:delay
302
Trigger:source
303
3 SCPI Error Messages
305
SCPI Error Messages
306
Command Errors
307
Execution Errors
308
Internal Errors
308
Query Errors
309
Calibration Errors
310
Advertisement
Keysight Technologies 34450A User Manual (117 pages)
5 1/2 Digit Multimeter
Brand:
Keysight Technologies
| Category:
Multimeter
| Size: 18.95 MB
Table of Contents
Declaration of Conformity
2
Safety Symbols
3
Regulatory Markings
4
General Safety Information
5
Environmental Conditions
8
Waste Electrical and Electronic Equipment (WEEE) Directive 2002/96/EC
9
Product Category
9
Sales and Technical Support
9
Additional Notices
10
Table of Contents
11
1 Getting Started Tutorial
19
Safety Information
2
1 Getting Started Tutorial
20
The Front Panel at a Glance
20
Figure 1-1 34450A Front Panel
20
Dual Display Screen
21
Figure 1-2 Typical Single Display Screen
21
Figure 1-3 Typical Dual Display Screen
21
Single Display Screen
21
Table 1-1 Table
21
The Display at a Glance
21
Display Annunciators
22
Table 1-3 Table
23
The Keypad at a Glance
24
Figure 1-4 34450A Keypad
24
Keypad Functions
24
Table 2-2 Table
26
Math Operations
26
Feature Upgrades
27
Table 2-4 Table
27
License Details
27
The Rear Panel at a Glance
28
Figure 1-5 Rear Panel at a Glance
28
Making Measurements
29
Using the Keys
29
Digit Masking
30
Selecting Current Input Terminals and Measurement Range
31
Measuring AC (RMS) or DC Voltage
31
Figure 1-6 ACV Rms and DCV Terminal Connection and Display
32
Measuring Resistance
33
Figure 1-7 2-Wire W Terminal Connection and Display
33
Figure 1-8 4-Wire W Terminal Connection and Display
33
Measuring AC (RMS) or DC Current up to 100 Ma
34
Figure 1-9 ACI Rms or DCI (Ma) Terminal Connection and Display
34
Measuring AC (RMS) or DC Current up to 10 a
35
Figure 1-10 ACI Rms or DCI (A) Terminal Connection and Display
35
Measuring Frequency for Voltage
36
Figure 1-11 Frequency Terminal Connection and Display
36
Measuring Frequency for Current
37
Figure 1-12 Frequency Terminal Connection and Display for ACI (Ma)
37
Figure 1-13 Frequency Terminal Connection and Display for ACI (A)
37
Testing Continuity
38
Figure 1-14 Continuity Test Terminal Connection and Display
38
Checking Diodes
39
Figure 1-15 Forward-Biased Diode Terminal Connection and Display
39
Figure 1-16 Reverse-Biased Diode Terminal Connection and Display
39
Measuring Temperature
40
Figure 1-17 Temperature Terminal Connection and Display
40
Measuring Capacitance
41
Figure 1-18 Capacitance Terminal Connection and Display
41
Selecting a Range
42
Remote Operation
43
USB Interface
43
Serial Interface
44
GPIB IEEE-488 (Optional)
45
Figure 1-19 Serial Interface Connector Diagram
45
Code Compatibility Mode
46
SCPI Commands
46
2 Functions and Features
47
Reset/Power-On State
47
Math Operations
48
Functions and Features Math Operations
48
Table 2-6 Table
48
Null Measurement
49
Figure 2-1 Accessing the Null Measurement
50
Figure 2-2 Accessing Hold Measurement
51
Hold Measurement
51
Limit Measurement
52
Accessing Math Menu
53
Editing Single Statistics
54
Editing All Statistics
55
Editing Db Measurement
56
Editing Dbm Measurement
57
Editing Math Functions Reference Values
58
Math Annunciators
58
Math Value Annunciators
58
Table 2-8 Table
58
Table 3-2 Table
58
Editing Values
59
The Dual Display
60
Measurements Available in Dual Display Mode
60
Using the Dual Display
61
Measurement Operation Frequencies for DCV-ACI
61
Using the Utility Menu
63
Figure 2-3 First Page of the Utility Menu
63
Figure 2-4 Second Page of the Utility Menu
63
Utility Menu Available Settings
64
RS232 Utility Sub-Menu
67
RS232 Utility Sub-Menu
68
GPIB Utility Sub-Menu
69
Reading Error Messages
70
The Beeper
71
Storing and Recalling Instrument States
72
Reset/Power-On State
74
Triggering the Multimeter
76
Figure 2-5 Trigger in Connector
77
Figure 2-6 Trigger out Connector
78
Data Logging
80
Data Log Menu Options
82
Viewing the Log Info
84
Viewing the Log List
85
Viewing the Log Histogram
86
Viewing the Log Statistics
87
Fluke 45/Fluke 8808A Code Compatibility Mode
88
Enabling the Code Compatibility Function
88
Notes for Fluke 45/Fluke 8808A Code Compatibility Mode
89
3 Measurement Tutorial
92
DC Measurement Considerations
92
Noise Rejection
93
Figure 3-1 Common Mode Rejection (CMR)
93
Figure 3-2 Noise Caused by Ground Loops
95
Measurement Speed Consideration
96
Dual Measurement Considerations
97
DC Voltage Dynamic Range in Dual Measurement
97
Voltage and Current in Dual Measurement
98
Figure 3-3 ADC Dynamic Range
98
Figure 3-4 Example of Measuring Voltage and Current in Dual
99
Resistance Measurement Considerations
100
Examples of Measurement Ranges
100
True RMS AC Measurements
103
Typical Errors for Various Pulse Waveforms as a
105
Other Primary Measurement Functions
107
Frequency Measurement Errors
107
DC Current Measurements
108
Capacitance Measurements
109
Temperature Measurements
111
Other Sources of Measurement Error
112
Specifications
115
Keysight Technologies 34450A Quick Start Up Manual (161 pages)
5 1/2 Digit Multimeter
Brand:
Keysight Technologies
| Category:
Multimeter
| Size: 11.79 MB
Table of Contents
English
6
Safety Information
2
Declaration of Conformity
2
Safety Symbols
3
Environmental Conditions
4
Table of Contents
6
Standard Shipped Items
7
The Front Panel at a Glance
8
The Display at a Glance
9
The Rear Panel at a Glance
10
Connecting the Power Cord and Powering on the Multimeter
11
Adjusting the Carrying Handle
12
Selecting Measurement Functions
13
Using the Dual Display
15
Using Math Functions
16
Connecting Test Leads to the Terminals
18
Français
26
Éléments Fournis en Standard
27
Le Panneau Avant D'un Coup D'œil
28
L'écran D'un Coup D'œil
29
Le Panneau Arrière D'un Coup D'oeil
30
Connexion du Cordon D'alimentation Et Mise en Marche du Multimètre
31
Réglage de la Poignée de Transport
32
Sélection des Fonctions de Mesure
33
Utilisation de L'affichage Double
35
Utilisation des Fonctions Mathématiques
36
Branchement des Cordons de Test Aux Bornes
38
Deutsch
46
IM Lieferumfang Enthaltenes Zubehör
47
Das Vordere Bedienfeld auf einen Blick
48
Die Anzeige auf einem Blick
49
Das Hintere Bedienfeld auf einen Blick
50
Anschließen des Netzkabels und Einschalten des Multimeters
51
Anpassen des Tragegriffs
52
Auswählen der Messfunktionen
53
Verwenden des Doppelanzeigenbildschirms
55
Verwenden von Mathematikfunktionen
56
Verbinden von Messleitungen mit Anschlüssen
58
Español
66
Elementos Estándar Incluidos
67
Breve Descripción del Panel Fronta
68
Breve Descripción de la Pantalla
69
Breve Descripción del Panel Posterior
70
Conecte el Cable de Alimentación y Encienda el Multímetro
71
Ajuste de la Manija
72
Selección de Funciones de Medición
73
Uso de la Pantalla Dual
75
Uso de las Funciones Matemáticas
76
Conexión de Cables de Prueba a Los Terminales
78
汉语
106
标准出货项
107
前面板概
108
显示屏一览
109
后面板一览
110
连接电源线并打开万用表电源
111
调整手提柄
112
选择测量功能
113
使用双显示屏
115
使用数学运算功能
116
将测试引线连接到端子
118
日本語
126
標準付属品
127
フロント・パネルの概要
128
ディスプレイの概要
129
リア・パネルの概要
130
電源コードの接続とマルチメータの電源投入
131
キャリング・ハンドルの調整
132
測定機能の選択
133
デュアル表示の使用
135
演算機能の使用
136
テスト・リードの端子への接続
138
표준 배송 품목
147
전면 패널 개요
148
디스플레이 개요
149
후면판 개요
150
전원 코드 연결 및 멀티미터 켜기
151
운반 손잡이 조절
152
측정 기능 선택
153
듀얼 디스플레이 사용
155
연산 기능 사용
156
단자에 테스트 리드 연결
158
Advertisement
Advertisement
Related Products
Keysight Technologies Truevolt 34465A
Keysight Technologies Truevolt 34460A
Keysight Technologies Truevolt 34461A
Keysight Technologies Truevolt 34470A
Keysight Technologies 34420A
Keysight Technologies 34972A
Keysight Technologies 34921A
Keysight Technologies 34923A
Keysight Technologies 34924A
Keysight Technologies 34925A
Keysight Technologies Categories
Measuring Instruments
Test Equipment
Control Unit
Portable Generator
Power Supply
More Keysight Technologies Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL