Repair Information
2) TFT LCD lead wire handling
(1) TFT LCD lead wire handling
Apply the insulating tape to
prevent the lead wire from shock
damage.
3) Positions to apply conductive and
insulating tape.
(1) I/F PCB
Apply insulating tape (10 × 20mm) to cover
up the lead wire from I/F PCB ass'y.
(2) Between TFT Holder and Body
Apply conductive tape to prevent static electricity.
Apply insulating tape (4 × 55mm) as follows.
Fig. 051
Reference position
Fig. 054
Reference position
Fig. 056
(2) Flex storing
Store the flex in the gap in the
bottom cover.
Fig. 052
Fig. 055
18
Fig. 053