Network Connector
4.2
Power Supply Pins
Signal Name
GND
3V3
4.3
How to Connect Unused Network Connector Pins
For Ethernet versions of the Anybus CompactCom B40-1 it is recommended to terminate
Ethernet signals in the network interface if one of the Ethernet ports is unused. For the 10/100
Mb/s hardware version it is sufficient to terminate pair no. 1 and 2, for the port of concern,
while for the 1 Gb/s hardware version this has to be done for pair no. 1, 2, 3, and 4.
Fig. 24
Unused fibre optic connector pins should be connected as follows:
•
100R between TXP and TXN
•
820R between SDN and 3V3, resulting in 2 V on SDN
•
1k5 between SDP and 3V3, resulting in 1.5 V on SDP- Indicates that no signal is received. A
signal amplitude of 0.5 V is appropriate.
•
4k7 between SCL and 3V3
•
4k7 between SDA and 3V3
Other network signals may be left floating when not used.
Anybus
®
CompactCom B40-1 Design Guide
Type
Pin No.
Description
Power
2, 6, 10,
Ground
14, 18, 28,
Power and signal ground reference.
32, 36, 40,
44, 52
Power
1, 27, 51
3.3 V power supply.