10.6 Applicable Standards and Limits
10.6.1 EMC standards
EMC immunity to:
Generic standard EN 61000-6-2:2011 -06
Electromagnetic compatibility (EMC) – Part 6-2: Generic standards - Immunity for industrial
environments
ESD: EN 61000-4-2
HF irradiation (housing): EN 61000-4-3
HF carried by wire: EN 61000-4-6
EN 61000-4-4:
EN 61000-4-5:
EMC noise emission to:
Generic standard DIN EN 61000-6-4: Emission standard for industrial environments (Class A)
Kuhnke Vico (E 854 DE)
28-03-2019
8 kV under air discharge (severity 3),
4 kV under contact discharge (severity 2)
80 MHz ... 1000 MHz, 10 V/m, 80% AM (1 kHz)
1.4 GHz ... 2.0 GHz, 3 V/m, 80% AM (1 kHz)
2 GHz ... 2.7 GHz, 1 V/m, 80% AM (1 kHz)
150 kHz ... 80 MHz, 10 V, 80% AM (1 kHz)
Burst, severity 3
Surge, severity 3
The high energy of every pulse occurring in surge mode requires an
adequate external wiring by some means of lightning protection such as
lightning stroke current and surge arresters.