5.1.3 Installation

Consider the information below in order to achieve and maintain the front panel's ingress protection ratings:
Check that the opening intended for the panel has the dimensions specified in this manual.
Check that the edges of the opening are flat and smooth.
Drive in all screws until the front panel corner contacts the mounting panel.
NOTE
Twisting of unit or ingress of moisture
Incipient or complete touch screen damage or leakiness
 Verify that the material around the installation opening is hard enough to ensure that the
panel PC is mounted correctly at all times. In order to achieve the specified ingress
protection, the material must not warp under the load of the mounting bolts or operation.
IP66 is warranted only if the following requirements are met:
The mounting panel or cabinet door you are installing the unit it may be between 1.5 mm and 6 mm
thick.
Check that the smooth surface diverges from the opening by not more than ≤ 0.5 mm.
Check that the roughness of the surface the gasket rests upon is not more than ≤ 120 µm.

5.1.4 Front panel opening

Cut an opening into the control panel area where you wish to install the unit. Refer to the drawing to find the
correct dimensions.
Kuhnke Vico (E 854 DE)
28-03-2019
Front panel opening
Model
Kuhnke Vico 404
Kuhnke Vico 704
Kuhnke Vico 1004
Construction and Functionality
Width A
Height B
136 mm
96 mm
176 mm
136 mm
271 mm
186 mm