Kendrion Kuhnke Vico 404 User Manual

Touch panel with codesys hmi web terminal with html 5 browser
Table of Contents

Advertisement

Quick Links

User Manaual
Kuhnke Vico 404, 704, 1004
Touch Panel with CODESYS HMI
WEB Terminal with HTML 5 Browser
E 854 DE
28-03-2019

Advertisement

Table of Contents
loading

Summary of Contents for Kendrion Kuhnke Vico 404

  • Page 1 User Manaual Kuhnke Vico 404, 704, 1004 Touch Panel with CODESYS HMI WEB Terminal with HTML 5 Browser E 854 DE 28-03-2019...
  • Page 2: Table Of Contents

    Kendrion Kuhnke Automation GmbH Table of Contents Table of Contents 1 Preface ................................5 Legal Notice ............................5 1.1.1 Version Details ........................... 5 About this Manual ..........................5 1.2.1 Limitation of Liability ........................... 5 1.2.2 Terms of Delivery ..........................5 1.2.3 Copyright ............................
  • Page 3 Software References ........................42 10.3 Connection Examples ........................43 10.4 Dimensions ............................44 10.4.1 Kuhnke Vico 404 ..........................44 10.4.2 Kuhnke Vico 704 ..........................45 10.4.3 Kuhnke Vico 1004 .......................... 46 10.5 Durability Information ........................47 10.5.1 UV resistance of front film ......................47 10.5.2 Chemical resistance ........................
  • Page 4 Kendrion Kuhnke Automation GmbH Table of Contents 10.6.1 EMC standards..........................48 10.7 Regulations and Declarations......................49 10.7.1 Mark of conformity .......................... 49 10.8 Approvals ............................49 10.9 Order Specifications ......................... 50 10.9.1 Basic units ............................50 10.9.2 Accessories ............................ 51...
  • Page 5: Preface

    - on whatever grounds - are excluded, except in instances of deliberate intent or gross negligence on our part. 1.2.2 Terms of Delivery The general conditions of sales and service of Kendrion Kuhnke Automation GmbH shall apply. 1.2.3 Copyright © Kendrion Kuhnke Automation GmbH This instruction manual is proprietary and protected by copyright.
  • Page 6: Warranty

    Kendrion Kuhnke Automation GmbH Preface 1.2.4 Warranty Warranty is subject to the provisions of the conditions of sale of Kendrion Kuhnke Automation GmbH or any contractual agreements between the parties. Kuhnke Vico (E 854 DE) 28-03-2019...
  • Page 7: Reliability, Safety

    Kendrion Kuhnke Automation GmbH Reliability, Safety 1.3 Reliability, Safety 1.3.1 Applicability For reasons of personal safety and to avoid material damages when working with or handling this Kuhnke product, you are advised to take heed of the notes and information contained in this instruction manual.
  • Page 8: Hazard And Other Warnings

    Kendrion Kuhnke Automation GmbH Reliability, Safety 1.3.5 Hazard and Other Warnings Despite the actions described in section 1.3.4, the occurrence of faults or errors in electronic control units - even if most highly improbable - must be taken into consideration.
  • Page 9: Electromagnetic Compatibility

    Kendrion Kuhnke Automation GmbH Reliability, Safety  Take particular heed of the hazard warnings Information To achieve a high degree of conceptual safety in planning and installing an electronic controller, it is essential to exactly follow the instructions given in the manual because wrong handling could lead to rendering measures against dangers ineffective or to creating additional dangers.
  • Page 10 Kendrion Kuhnke Automation GmbH Reliability, Safety Refer to IEC 61131-4, User's Guideline, for general installation instructions to be complied with to ensure that hardware interface factors and the ensuing noise voltages are limited to tolerable levels. Interference emission Interfering emission of electromagnetic fields, HF...
  • Page 11 Kendrion Kuhnke Automation GmbH Reliability, Safety Inductive actuators Switching off inductances (such as from relays, contactors, solenoids or switching magnets) produces surge voltages. It is necessary to reduce these extra voltages to a minimum. Throttling elements could be diodes, Z-diodes, varistors or RC elements. Their rating should conform to the specifications provided by the manufacturer or supplier of the actuators.
  • Page 12: System Description

    Kendrion Kuhnke Automation GmbH System Description 2 System Description 2.1 Kuhnke Vico Kuhnke's new Vico 04 series is comprised of a powerful display unit of an industry-ready design made with modern methods of operation in mind. Run the CODESYS HMI software package installed to let a remote Kuhnke Vico 04 machine display data from one or any greater number of CODESYS control units.
  • Page 13: Product Description

    It is designed for on-site use immediately at the machine. Machine, system and switching cabinet makers particularly benefit from Kuhnke Vico as a low-cost visualisation system. Front view of Kuhnke Vico 404 Front view of Kuhnke Vico 704 Front view of Kuhnke Vico 1004...
  • Page 14: Applicability And Intended Use

    Kendrion Kuhnke Automation GmbH Product Description 3.1.1 Applicability and Intended Use Kuhnke's panel is designed for on-site use in industrial environments immediately at the machine. It installs in switching cabinets, switching or control panels. This series of devices provides devices and equipment manufacturing with a visualisation unit for different...
  • Page 15: Technical Data Of Kuhnke Vico

    Kendrion Kuhnke Automation GmbH Product Description 3.2 Technical Data of Kuhnke Vico General Specifications Product name Vico 404 Vico 704 Vico 1004 Screen size / resolution 4.3" / 480 x 272 (PSP) 7" / 800 × 480 (WVGA) 10.1" / 1024x600, WSVGA Brightness 200 cd/m²...
  • Page 16: Construction And Functionality

    Kendrion Kuhnke Automation GmbH Construction and Functionality 4 Construction and Functionality 4.1 Brief Description Front film Screen opening Front frame Name plate and software licences Connectors 4.2 Labelling and Identification Name plate Name for ordering Type : CODESYS HMI Part number...
  • Page 17: Serial Number

    Kendrion Kuhnke Automation GmbH Construction and Functionality 4.2.1 Serial Number The serial number is a numerical code incorporating the production date and a serial number. Make-up of serial number: YY MM DD NNNNN Example: The unit shown above was manufactured on 05th June 2015 and has the serial number 00039.
  • Page 18: Transport And Storage

    Kendrion Kuhnke Automation GmbH Construction and Functionality 4.4 Transport and Storage Despite the unit's rugged construction, its components inside are still sensitive to impact and vibration. Transport and keep Kuhnke Vico in its original packaging and ensure that the ambient conditions are as specified at all times during transport and storage.
  • Page 19: Connectors Of Kuhnke Vico

    Kendrion Kuhnke Automation GmbH Construction and Functionality 4.5 Connectors of Kuhnke Vico All external connectors are located on the back of Kuhnke Vico. All connectors are of the plug-in type. power supply (24 V DC -10…32 VDC) serial port, "COM"...
  • Page 20: Serial Port, "Com

    Kendrion Kuhnke Automation GmbH Construction and Functionality http://de.wikipedia.org/wiki/Datei:Functional_Earth.svg Information A low-impedance earth conductor improves the dissipation of interference received via external power supply cables, signal cables or cables of peripheral units. 4.5.3 Serial Port, "COM" The port is not electrically insulated.
  • Page 21: Ethernet Port, "Lan

    Kendrion Kuhnke Automation GmbH Construction and Functionality 4.5.4 Ethernet Port, "LAN" The on-board 10/100 Mbit base-T Ethernet adapter attaches the unit to a network through its RJ-45 connector. The LEDs labelled "LNK" and "RCV" tell you whether the unit is properly connected to the network.
  • Page 22: Usb Port, "Usb

    Kendrion Kuhnke Automation GmbH Construction and Functionality 4.5.5 USB Port, "USB" Pin wiring X4 / X5 Connector Function NOTE USB port overload by excessive power consumption Machine failure and/or data loss  Only attach USB peripherals whose total power needs do not exceed 0.5 A or supply external power to the USB peripherals by adding an active hub to the line, for example.
  • Page 23: Installation And Operation

    Kendrion Kuhnke Automation GmbH Construction and Functionality 5 Installation and Operation Information Before installing, servicing or putting Kuhnke Vico into operation, please also read the safety information in the preface of this document. 5.1 Mechanical Installation Kuhnke Vico is a modern electronic assembly. Handle - specifically mount, operate and service - with care.
  • Page 24: Installation

    Kendrion Kuhnke Automation GmbH Construction and Functionality 5.1.3 Installation Consider the information below in order to achieve and maintain the front panel's ingress protection ratings:  Check that the opening intended for the panel has the dimensions specified in this manual.
  • Page 25: Mounting Elements

    Kendrion Kuhnke Automation GmbH Construction and Functionality 5.1.5 Mounting elements Insert the unit in the front panel opening and put in the mounting clips as shown in the drawing below. Tighten the screws of the mounting clips to 75 Nm or tighten them until the front panel edges contact the mounting panel.
  • Page 26: Electrical Installation

    Kendrion Kuhnke Automation GmbH Construction and Functionality 5.2 Electrical Installation The connectors are located on the back of Kuhnke Vico or as described in section Connectors of Kuhnke Vico. Proceed in the order below to wire up the unit:  turn off the unit, ...
  • Page 27 Kendrion Kuhnke Automation GmbH Construction and Functionality Power supply fusing The cord must have external protection against short circuit and overload triggering at max. 10 A, min. 60 V. Power supply wiring example Kuhnke Vico (E 854 DE) 28-03-2019...
  • Page 28: Putting Into Service

    Kendrion Kuhnke Automation GmbH Construction and Functionality 5.3 Putting into Service 5.3.1 General start-up information Have the following tools at hand for starting the unit for the first time:  A USB keyboard  A USB mouse Touch screen operation Control objects on the touch screen are operated by applying a slight but noticeable pressure on them with your finger or the touch stylus.
  • Page 29: Turning On The Unit

    Kendrion Kuhnke Automation GmbH Construction and Functionality 5.3.3 Turning on the unit Connect the unit to the power supply. The user interface of the operating system displays after the boot-up routine. Remember that the display resolution is set in the Image. In case the unit is equipped with a CODESYS HMI, it will start automatically and display its status on the welcom screen.
  • Page 30: Configuration

    Kendrion Kuhnke Automation GmbH Construction and Functionality 5.4 Configuration The Vico X04 is configured via the integrated user interface "system settings". The user interface can be accessed directly on the device or remotely via a web browser. 5.4.1 IP address Vico X04 is delivered with a permanent IP address and subnet mask setting.
  • Page 31: Diagnosis

    Kendrion Kuhnke Automation GmbH Construction and Functionality 5.5 Diagnosis 5.5.1 General Information Under extreme ambient conditions such as high humidity and temperature, the touch screen surface may sometimes develop some undulation. This is a purely optical effect and no functional constraint.
  • Page 32: Maintenance / Servicing

    Kendrion Kuhnke Automation GmbH Construction and Functionality 5.6 Maintenance / Servicing 5.6.1 General Only qualified persons are allowed to work on Kuhnke Vico. CAUTION Wrong or excessive supply voltage Electric shock hazard  Do not plug, mount, unplug or touch the connectors during operation! You may otherwise provoke destruction or malfunction.
  • Page 33: Durability

    Kendrion Kuhnke Automation GmbH Construction and Functionality 5.7 Durability 5.7.1 Repairs / customer service Information Only the manufacturer or customer service providers authorised by the manufacturer are allowed to do repairs and perform corrective maintenance. 5.7.2 Warranty The statutory period and conditions of warranty apply. Warranty expires if unauthorised attempts are made to repair the unit / product or any other intervention is performed.
  • Page 34: Specific Device Functions

    6.1.2 Restricting access 6.2 Splash Screen You may display a picture while the unit is booting. The factory default is to show a Kendrion tile. The graphic can be exchanged or deleted in the "System Settings" in the menu item "Management".
  • Page 35: Codesys V3 Development Environment

    Kendrion Kuhnke Automation GmbH Construction and Functionality 7 CODESYS V3 Development Environment 7.1 Installing CODESYS on the Project Engineering PC CODESYS is a device-independent system for programming control units. It conforms to standard IEC 61131-3 and supports all standardised IEC programming languages plus the integration of C code routines and object-orientated programming.
  • Page 36 Kuhnke Vico x04 LX HMI.devdesc.xml Kuhnke Vico 704 HMI Kuhnke Vico 1004 HMI Device description download The current Device Description can be found in the product finder at kendrion.com or contact Kendrion product management. Kuhnke Vico (E 854 DE) 28-03-2019...
  • Page 37: Web Terminal Functions

    Kendrion Kuhnke Automation GmbH Construction and Functionality 8 Web Terminal Functions 8.1 Chromium Chromium is an HTML5-based web browser. It is an open source project originally launched by Google. It is already installed on Kuhnke Vico 04 Web units. Enable the "full screen standalone" option to use the browser for displaying web-based visualisations of systems and machines.
  • Page 38: Setting For Codsys Web Visu

    The following settings should be made when using the Vico WEB terminal to display CODESYS WEB visualizations.  On startup -> Open Homepage  Homepage e.g. for a Kendrion Starterkt: http://192.168.0.113:8080/webvisu.htm  Tool Bar -> Enable Tool Bar: Activated 9 Systems Settings 9.1 Activation of Systems Settings...
  • Page 39 Kendrion Kuhnke Automation GmbH Construction and Functionality Kuhnke Vico (E 854 DE) 28-03-2019...
  • Page 40: Using The Chromium Browser's "Setting Page

    Kendrion Kuhnke Automation GmbH Construction and Functionality 9.1.2 Using the Chromium browser's "Setting page" If the unit is set to running the browser at start-up, you can display the "Settings page" by keeping the top left corner of the touch screen pressed for several seconds. One item on the menu bar takes you to the "System Settings"...
  • Page 41: System Settings Functions

    Kendrion Kuhnke Automation GmbH Construction and Functionality 9.2 System Settings Functions: The system settings include options for the basic settings of the device. Functions Language Configure language used for System Setting menu only. System Show informations about platform, status and timers (like System on time, backlight on time).
  • Page 42: Appendix

    Kendrion Kuhnke Automation GmbH Construction and Functionality 10 Appendix 10.1 Software Copyrights The unit's software contains product components of third-party software makers. This section summarises the copyright details regarding the software resources concerned. CODESYS Control runtime system Equipment manufacturers installing the CODESYS runtime system on their devices are sent a licence file...
  • Page 43: Connection Examples

    Kendrion Kuhnke Automation GmbH Construction and Functionality 10.3 Connection Examples Kuhnke Vico (E 854 DE) 28-03-2019...
  • Page 44: Dimensions

    Kendrion Kuhnke Automation GmbH Construction and Functionality 10.4 Dimensions 10.4.1 Kuhnke Vico 404 Kuhnke Vico (E 854 DE) 28-03-2019...
  • Page 45: Kuhnke Vico 704

    Kendrion Kuhnke Automation GmbH Construction and Functionality 10.4.2 Kuhnke Vico 704 Kuhnke Vico (E 854 DE) 28-03-2019...
  • Page 46: Kuhnke Vico 1004

    Kendrion Kuhnke Automation GmbH Construction and Functionality 10.4.3 Kuhnke Vico 1004 Kuhnke Vico (E 854 DE) 28-03-2019...
  • Page 47: Durability Information

    Kendrion Kuhnke Automation GmbH Construction and Functionality 10.5 Durability Information 10.5.1 UV resistance of front film The unit was designed for indoor application. Provided that it is not exposed to direct UV radiation and kept at 25 °C, it is expected to last for 10 years.
  • Page 48: Applicable Standards And Limits

    Kendrion Kuhnke Automation GmbH Construction and Functionality 10.6 Applicable Standards and Limits 10.6.1 EMC standards EMC immunity to:  Generic standard EN 61000-6-2:2011 -06 Electromagnetic compatibility (EMC) – Part 6-2: Generic standards - Immunity for industrial environments  ESD: EN 61000-4-2...
  • Page 49: Regulations And Declarations

    Kendrion Kuhnke Automation GmbH Construction and Functionality 10.7 Regulations and Declarations 10.7.1 Mark of conformity The EC-Declarations of Conformity and the associated documentation can be made available to the competent authorities pursuant to the above EU Directive. Please contact the Project Management, as necessary.
  • Page 50: Order Specifications

    Kendrion Kuhnke Automation GmbH Construction and Functionality 10.9 Order Specifications 10.9.1 Basic units Technical data Kuhnke Vico 404 HMI 677 800 00 Touch Panel with CODESYS V3 HMI 4.3" display, resolution (4.3") 480 x 272 (PSP) ARM Cortex-A8 - 1 GHz...
  • Page 51: Accessories

    Kendrion Kuhnke Automation GmbH Construction and Functionality 10.9.2 Accessories Kuhnke Vico (E 854 DE) 28-03-2019...
  • Page 52 Kendrion Kuhnke Automation GmbH Industrial Control Systems Lütjenburger Str. 101 23714 Malente Tel.: +49 4523 402 0 Fax: +49 4523 402 201 sales-ics@kendrion.com www.kendrion.com...

This manual is also suitable for:

Kuhnke vico 1004Kuhnke vico 704

Table of Contents