J4060-03
12G SAS JBOD Series
User's Manual
UM_4060-03_v1_072219

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the 12G SAS JBOD Series and is the answer not in the manual?

Questions and answers

Summary of Contents for AIC 12G SAS JBOD Series

  • Page 1 J4060-03 12G SAS JBOD Series User's Manual UM_4060-03_v1_072219...
  • Page 2: Table Of Contents

    3.5.1 How to enable/disable T10 zoning ..............27 3.5.2 How to configure T10 zoning ................28 3.5.3 How to get all revisions in AIC SAS 12G Expander ........30 3.5.4 How to configure temperature sensor(HUB only) .......... 31 3.5.5 How to configure enclosure address .............. 32 3.5.6 How to configure standby timer for all disk drives(EDGE only) ....
  • Page 3 3.5.8 How to configure serial number ..............36 3.5.9 How to power off/on all disk drives automatically ........37 3.5.10 How to configure EDFB (EDGE only) ............. 38 3.5.11 How to configure power setting (HUB only) ..........39 3.5.12 How to configure zone count ................ 41 3.5.13 How to configure multiple ''up'' ports ( HUB only) ........
  • Page 4 Copyright © 2019 AIC, Inc. All Rights Reserved. This document contains proprietary information about AIC products and is not to be disclosed or used except in accordance with applicable agreements.
  • Page 5 Document Release History Release Date Version Update Content July User's Manual release to public. 2019...
  • Page 6: Preface

    Disclaimer AIC shall not be liable for technical or editorial errors or omissions contained herein. The information provided is provided "as is" without warranty of any kind. To the extent permitted by law, neither AIC or its affiliates, subcontractors or suppliers will be liable for incidental, special or consequential damages including downtime cost;...
  • Page 7: Safety Instructions

    Safety Instructions Before getting started, please read the following important cautions: • All cautions and warnings on the equipment or in the manuals should be noted. • Most electronic components are sensitive to electrical static discharge. Therefore, be sure to ground yourself at all times when installing the internal components. •...
  • Page 8 • If one of the following situations arise, the equipment should be checked by service personnel: 1. The power cord or plug is damaged. 2. Liquid has penetrated the equipment. 3. The equipment has been exposed to moisture. 4. The equipment does not work well or will not work according to its user manual. 5.
  • Page 9: About This Manual

    Chapter 4 Technical Support For more information or suggestion, please verify and contact the nearest AIC corporation representative in your district or visit the AIC website: http://www.aicipc.com/en/ . It is our pleasure to provide the best service for our customers.
  • Page 10: Chapter 1� Product Features

    Chapter 1� Product Features J4060-03 User Manual Chapter 1. Product Features Before removing the subsystem from the shipping carton, visually inspect the physical condition of the shipping carton. Exterior damage to the shipping carton may indicate that the contents of the carton are damaged. If any damage is found, do not remove the components;...
  • Page 11: Specifications

    J4060-03 User Manual Chapter 1. Product Features 1.2 Specifications Number of 2 x External expanders Expander 6 x Internal expanders Broadcom SAS3x36R + General Expander Chip Broadcom SAS3x48 Host/Expansion 6 x Mini SAS HD (SFF-8644) Interface per expander module 12Gb & 6Gb SAS if using dual expanders Drive Interface 12Gb &...
  • Page 12: 1�3 Feature

    J4060-03 User Manual Chapter 1. Product Features 1�3 Feature J4060-03 is a reliable SAS JBOD with 3.5” x 60 hotswap drives bays. This product is designed to accommodate 2 external expanders and 6 internal expander with 6 Mini SAS HD per expander module. Featuring the expander chip, Broadcom SAS3x36R and SASx48, which is emphasized for its 36 and 48 phy edge expansion and performance of supporting up to 12 Gb/s, this product enhances these features by integrating hotswap designs, redundant fans, and expansion to offer easy control and high performance for...
  • Page 13 J4060-03 User Manual Chapter 1. Product Features Front Panel Fault LED (red) Interpretation The drives has failed, or a predictive failure alert has been received for the drives.
  • Page 14 J4060-03 User Manual Chapter 1. Product Features Rear Expander Panel Console port SFF-8644 wide port Debug port Identify LED indicator BMC LAN port BMC console port Rear Panel 1200W 1+1 hot swap redudant PSU Secondary Primary Mini SAS HD 4 x 80x38mm hot swap fan...
  • Page 15 J4060-03 User Manual Chapter 1. Product Features 1.4 8644 with Zoning Configuration and 8644 Port Definition There are 3 kinds of zoning options that can be implemented by Command Line interface operation (see Chapter 3 for reference). By using the zoning option, four of the 8644 ports will have a variety of zone group settings.
  • Page 16 J4060-03 User Manual Chapter 1. Product Features Zone count 1: 60 drives per zone. All SFF8644 ports and drives are at the same zone group. (SEE FIGURE BELOW). Zone count 1: GROUP 1 Top View Top View Top View 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 Left Edge Center Edge Right Edge...
  • Page 17 J4060-03 User Manual Chapter 1. Product Features Zone count 2: 30 drives per zone. Port 1 & Port 2 & Port 3 are at zone group 1, Port 4 & Port 5 & Port 6 are at zone group 2 (SEE FIGURE BELOW). Top View Top View Top View...
  • Page 18 J4060-03 User Manual Chapter 1. Product Features Zone count 4: 15 drives & Port 1 are at zone group 1, 15 drives & Port 2 are at zone group 2, 15 drives & Port 3 are at zone group 3, 15 drives & port 4 are at zone group 4. (SEE FIGURE BELOW) Top View Top View...
  • Page 19: Chapter 2� Hardware Setup

    Chapter 2� Hardware Setup J4060-03 User Manual Chapter 2. Hardware Setup 2�1 Top Cover NOTE The JBOD consists of two top covers with corresponding release buttons on both sides of the chassis. One cover slides toward the front panel to open, while the other slides toward the rear panel for removal.
  • Page 20: 2�2 Power Supply Unit Module

    J4060-03 User Manual Chapter 2. Hardware Setup 2�2 Power Supply Unit Module  Push the ejector to release the module.  Pull the handle to remove the module out of the chassis.  Push the replaced power supply unit into the chassis. Ensure that the module is hooked into the cage.
  • Page 21: 2�3 Fan Module

    J4060-03 User Manual Chapter 2. Hardware Setup 2�3 Fan Module  Unplug the cables and connectors.  Loosen the captive screws to remove the fan.  Pull the fan module from the chassis.  Insert the replaced fan into the chassis and tighten the captive screws. Loosen screw.
  • Page 22: 2�4 Hard Disk Drive

    J4060-03 User Manual Chapter 2. Hardware Setup 2�4 Hard Disk Drive 2�4�1 Install Hard Disk Drive  Pull the tray lever open.  Pull the tray lever outward completely.  Pull the tray out of the system. Open tray lever. Lift.
  • Page 23: Drive Slot Map

    J4060-03 User Manual Chapter 2. Hardware Setup 2�4�2 Drive Slot Map The drive slot map follows. Left Edge Center Edge Right Edge...
  • Page 24: 2�5 Hdd Backplane Module

    J4060-03 User Manual Chapter 2. Hardware Setup 2�5 HDD Backplane Module  Remove the LED board by loosening the captive screws.  Pull the HDD backplane from the chassis.  Insert a new HDD backplane into the chassis and close the lever. ...
  • Page 25: 2�6 Expander

    J4060-03 User Manual Chapter 2. Hardware Setup 2�6 Expander  Loosen the thumb screw to release expander tray lever.  Hold the lever to pull the expander out of the enclosure.  Align the expander module with the opening in front of the enclosure and insert it firmly into the enclosure.
  • Page 26: 2�7 Bmc Module

    J4060-03 User Manual Chapter 2. Hardware Setup 2�7 BMC Module  Dislodge the BMC module from the carrier board.  Remove the BMC module.  Align the BMC module on the carrier board  Place the BMC module onto the carrier board.
  • Page 27: 2�8 Slide Rail Installation

    J4060-03 User Manual Chapter 2. Hardware Setup 2�8 Slide Rail Installation To install the slide rail, please refer to the manual in the slide rail kit. Option 1: AP61-843 Slide Rail Screw Sack User’s Manual Option 2 : AP61-920 Slide Rail Screw Sack User’s Manual...
  • Page 28: Chapter 3. Sub-System Configuration Setup

    AIC 12G Expander Controller NOTE To have multiple host access support (the host number can be up to the number of wide ports on each AIC 12G expander controller), only the following drives are supported for shared access: 1. SAS drive/nearline SAS drive 2.
  • Page 29: 3�2 Connect Host To Jbod Via Rs232

    J4060-03 User Manual Chapter 3. Sub-system Configuration Setup 3�2 Connect Host to JBOD via RS232 Use a RS-232 DB9 cable to connect the console port of JBOD with host's PC COM port (see figures below for DB9 RS-232 cable and SAS expander COM port).
  • Page 30: 3�3 Utility Setup On Host

    J4060-03 User Manual Chapter 3. Sub-system Configuration Setup 3�3 Utility Setup on Host Step 1: Set up host RS232 connection Set up RS232 connection application into your host as shown in the example process below. For example: OS: Microsoft Windows Server 2008 RS232 connection application: Hyperterminal Step 2: Install HyperTrm.exe...
  • Page 31 J4060-03 User Manual Chapter 3. Sub-system Configuration Setup Step 3: Enter a new name for the icon in the field below and click OK. Step 4: Connect by using selecting an option in the drop down menu circled in red below (we selected COM2 in this example) and click...
  • Page 32 J4060-03 User Manual Chapter 3. Sub-system Configuration Setup Step 5: Under “Bits per second,” select 38400. Under “Flow control,” select: None. Click OK when you have finished your selections. Step 6: After step 5, you will enter hyper terminal screen. Then please press key and the cmd line will appear on the screen.
  • Page 33: Update Firmware And Mfg Through Console Port

    J4060-03 User Manual Chapter 3. Sub-system Configuration Setup 3.4 Update Firmware and MFG through Console Port Step 1: Please input “fdl 0 0” in command line to update the firmware. Step 2: Select the tool bar ''Transfer'' → ''Send File'' within 10 seconds.
  • Page 34 J4060-03 User Manual Chapter 3. Sub-system Configuration Setup Step 3: Select the Firmware file and set the Protocol type as “Xmodem.” Press the “Send” button. 4U60swap Step 4: After completing the FW update, “ Buffer Download Complete” will appear on the screen.
  • Page 35 J4060-03 User Manual Chapter 3. Sub-system Configuration Setup Step 5: Input “fdl 83 0 ” in commond line to update the MFG. Step 6: Go to the Transfer menu and then select “Send file” within 10 seconds. Step 7: Select the MFG file and set the Protocol type as “Xmodem.” Press the “Send”...
  • Page 36: Configure Command Line Interface Operation

    J4060-03 User Manual Chapter 3. Sub-system Configuration Setup 3.5 Configure Command Line Interface Operation 3.5.1 How to enable/disable T10 zoning The default T10 zoning configuration is off. (A) Check the current zoning state cmd> phyzone state Zoning is OFF (B) Enable zoning cmd>...
  • Page 37: How To Configure T10 Zoning

    J4060-03 User Manual Chapter 3. Sub-system Configuration Setup 3.5.2 How to configure T10 zoning After enabling T10 zoning, senven predefined groups are Group1, Group8, Group9, Group10, Group11, Group 12 and Group 13. Each PHY should be in one of the seven groups, and all PHYs in a wide port should be in the same group.
  • Page 38 J4060-03 User Manual Chapter 3. Sub-system Configuration Setup...
  • Page 39: How To Get All Revisions In Aic Sas 12G Expander

    J4060-03 User Manual Chapter 3. Sub-system Configuration Setup 3.5.3 How to get all revisions in AIC SAS 12G Expander (A) Expander firmware revision cmd> rev (B) Expander configuration revision cmd> showmfg (C) MCU firmware revision or sensor information (MCU firmware revision is reported by Hub only) cmd>...
  • Page 40: How To Configure Temperature Sensor(Hub Only)

    J4060-03 User Manual Chapter 3. Sub-system Configuration Setup 3.5.4 How to configure temperature sensor(HUB only) Four temperature settings in Celsius are T1, T2, warning threshold, and alarm (critical) threshold. The T1, T2 and alarm (critical) threshold are applied to the smart fan funcion. (A) Get the current temperature settings cmd>...
  • Page 41: How To Configure Enclosure Address

    J4060-03 User Manual Chapter 3. Sub-system Configuration Setup 3.5.5 How to configure enclosure address (A) Get the current enclosure address cmd> enclosure_addr Enclosure Address: 0x500605B0000272BF (B) Set the enclosure address with 0x500605B0000272BF. The new setting will take effect after reset. cmd>...
  • Page 42: How To Configure Standby Timer For All Disk Drives(Edge Only)

    J4060-03 User Manual Chapter 3. Sub-system Configuration Setup 3.5.6 How to configure standby timer for all disk drives(EDGE only) This feature is applicable for SAS/SATA drives. Standby timer is in units of minutes. Setting standby timer with 0 minute disables this feature. (A) Get current standby timer cmd>...
  • Page 43: How To Configure Wide Port Checker

    This feature is applicable for SAS drives instead of SATA drives. If there is no connection with any active SAS initiator by checking all wide ports, AIC Expander Controller stops all attached SAS drives to save power consumption of SAS drives. Otherwise, AIC Expander Controller starts all attached SAS drives to provide drive access service to any active SAS initiator.
  • Page 44 J4060-03 User Manual Chapter 3. Sub-system Configuration Setup...
  • Page 45: How To Configure Serial Number

    J4060-03 User Manual Chapter 3. Sub-system Configuration Setup 3.5.8 How to configure serial number (A) Get the current serial number cmd> serial_number Expander number: 421-12021704510010 or Expander number: 421-12021704510010 Enclosure number: 526-12071100500088 (B) Only set Expander serial number with 421-12021704510010. cmd>...
  • Page 46: How To Power Off/On All Disk Drives Automatically

    This feature is applicable for SAS/SATA drives. If there is no connection with any active SAS initiator by checking all wide ports, AIC Expander Controller powers off all attached SAS/ SATA drives to save power consumption. Otherwise, AIC Expander Controller powers on all attached SAS/SATA drives to provide drive access service to any active SAS initiator.
  • Page 47: How To Configure Edfb (Edge Only)

    J4060-03 User Manual Chapter 3. Sub-system Configuration Setup 3.5.10 How to configure EDFB (EDGE only) The default EDFB configuration is off. (A) Check the current configuration cmd> edfb EDFB is OFF (B)Enable the edfb cmd>edfb on (C)Disable the edfb cmd> edfb off...
  • Page 48: How To Configure Power Setting (Hub Only)

    J4060-03 User Manual Chapter 3. Sub-system Configuration Setup 3.5.11 How to configure power setting (HUB only) This feature is for restoring on AC power loss. Three supported options are "keep off", "keep on", and "keep last state". The default setting is "keep off". (A) Get the current power setting cmd>...
  • Page 49 J4060-03 User Manual Chapter 3. Sub-system Configuration Setup...
  • Page 50: How To Configure Zone Count

    J4060-03 User Manual Chapter 3. Sub-system Configuration Setup 3.5.12 How to configure zone count Remove the SAS cable between the HBA/RAID card and the J4U60-01before configuring zone count. Power the J4U60-01 off after configuring zone count. Power on the J4U60-01, and then insert the SAS cable. Three zone configurations supported are one zone(default), two zones, and four zones.
  • Page 51 J4060-03 User Manual Chapter 3. Sub-system Configuration Setup (C) Predefined zones follow. (C-1) When Zone Count = 1, T10 zoning is disabled. HUB: Zone # Wideport 1,2,3,4,5,6 EDGE: Zone # Slot 1~60 (C-2) When Zone Count = 2, T10 zoning is enabled. HUB: Zone # Wideport...
  • Page 52: How To Configure Multiple ''Up'' Ports ( Hub Only)

    J4060-03 User Manual Chapter 3. Sub-system Configuration Setup 3.5.13 How to configure multiple ''up'' ports ( HUB only) This feature can support multiple "up" ports when the zone count = 1. (A) Configure Port-1 and Port-2 to be "up" ports. Port-1 is composed of PHY 8 ~ 11, and Port-2 is composed of PHY 4 ~ 7.
  • Page 53: 3�6 Ses Inband Features

    J4060-03 User Manual Chapter 3. Sub-system Configuration Setup 3�6 SES Inband Features To ensure J4060-03 can work properly and provide high performance, durability. J4060-03 has implemented SCSI Enclosure Services to monitor the status of power supply, system cooling fan and working temperature. It also has the indicators to deliver the status of fail devices such as power supply or cooling fan.
  • Page 54: Implementation On Ses

    J4060-03 User Manual Chapter 3. Sub-system Configuration Setup 3.6.3 Implementation on SES Pages 3.6.3.1 SES String In Page Get PMBUS information with String In Page. String In Format Byte 0 I2C congestion status (0: no congestion, 1: congestion or failure) Byte 1~2 PSU Module1 STATUS_WORD Byte 3~4...
  • Page 55 J4060-03 User Manual Chapter 3. Sub-system Configuration Setup 3.6.3.3 SES Vendor specific page: Chassis Number ( page code 82h) Out / In The length N of chassis number can be 0 to 30 bytes. If no chassis number is entered (N=0), then chassis number is cleared.
  • Page 56 J4060-03 User Manual Chapter 3. Sub-system Configuration Setup 3.6.3.4 SES Vendor specific page: Canister Number ( page code 83h) Out / In The length N of canister number can be 0~30 bytes. If no canister number is entered (N=0), then canister number is restored to default: 0x20 0x20 0x20 0x20 0x20 0x20 0x20 0x20 (8 spaces in ASCII).
  • Page 57: Implementation On Ses Elements

    J4060-03 User Manual Chapter 3. Sub-system Configuration Setup 3�6�4 Implementation on SES Elements Only the fields highlighted in green are supported. 3.6.4.1. Power Supply Element (A) Power Supply Control Element BYTE/BIT COMMON CONTROL SELECT PRDFAIL DISABLE Reserved SWAP RQST Reserved IDENT Reserved RQST...
  • Page 58 J4060-03 User Manual Chapter 3. Sub-system Configuration Setup 3.6.4.2 Cooling Element (A) Cooling Control Element BYTE/BIT COMMON CONTROL SELECT PRDFAIL DISABLE Reserved SWAP RQST Reserved IDENT RQST Reserved RQST ON Reserved REQUESTED SPEED CODE FAIL Field Value RQST IDENT Please refer to section “SES Element Control Functions” for details. REQUESTED Please refer to section “SES Element Control Functions”...
  • Page 59 J4060-03 User Manual Chapter 3. Sub-system Configuration Setup 3.6.4.3 Temperature Sensor Element (A) Temperature Sensor Control Element BYTE/BIT COMMON CONTROL SELECT PRDFAIL DISABLE Reserved SWAP RQST RQST Reserved IDENT FAIL Reserved Reserved (B) Temperature Sensor Status Element BYTE/BIT COMMON STATUS Reserved PRDFAIL DISABLE SWAP ELEMENT STATUS CODE...
  • Page 60 J4060-03 User Manual Chapter 3. Sub-system Configuration Setup 3.6.4.4 Enclosure Element (A) Enclosure Control Element BYTE/BIT COMMON CONTROL SELECT PRDFAIL DISABLE Reserved SWAP RQST Reserved IDENT POWER CYCLE POWER CYCLE DELAY REQUEST REQUEST REQUEST POWER OFF DURATION FAILURE WARNING Field Value RQST IDENT Please refer to section “SES Element Control Functions”...
  • Page 61 J4060-03 User Manual Chapter 3. Sub-system Configuration Setup 3.6.4.5 Voltage Element (A) Voltage Control Element BYTE/BIT COMMON CONTROL SELECT PRDFAIL DISABLE Reserved SWAP RQST RQST Reserved IDENT FAIL Reserved Reserved (B) Voltage Status Element BYTE/BIT COMMON STATUS Reserved PRDFAIL DISABLE SWAP ELEMENT STATUS CODE WARN...
  • Page 62 J4060-03 User Manual Chapter 3. Sub-system Configuration Setup 3.6.4.6 Array Device Element (A) Array Device Control Element BYTE/BIT COMMON CONTROL SELECT PRDFAIL DISABLE Reserved SWAP RQST RQST RQST RQST RQST IN RQST RQST R/ RQST OK RSVD CONS IN CRIT FAILED REBULD/ R ABORT...
  • Page 63 J4060-03 User Manual Chapter 3. Sub-system Configuration Setup (B) Array Device Status Element BYTE/BIT COMMON STATUS Reserved PRDFAIL DISABLE SWAP ELEMENT STATUS CODE RSVD IN CRIT IN FAILED REBUILD/ DEVICE HOT SPARE CONS CHK ARRAY ARRAY REMAP ABORT ENCLOSURE READY DO NOT ENCLOSURE CLIENT...
  • Page 64: Ses Element Control Functions

    J4060-03 User Manual Chapter 3. Sub-system Configuration Setup 3�6�5 SES Element Control Functions 3.6.5.1 LED indicators (blue and red) associated with an attached disk drive Array Device Slot control element BYTE/BIT COMMON CONTROL SELECT PRDFAIL DISABLE Reserved SWAP RQST RQST RQST RQST RQST IN...
  • Page 65 We use the software package "sg3_utils" on Linux for example, and have a SAS HBA and a cable to connect your host with the expander. (A) Show the device for AIC Expander Controller (canister) $ sg_map -i /dev/sg2 AIC 12G 4U60swap: Edge-L 0c08 (B) Get the current state of a slot power.
  • Page 66 “PowerSupply02” to power off the entire enclosure. We use the software package "sg3_ utils" on Linux for example, and have a SAS HBA and a cable to connect your host with the expander. (A) Show the device for AIC Expander Controller (canister) $ sg_map -i /dev/sg2 AIC 12G 4U60swap: Hub...
  • Page 67 We use the software package "sg3_utils" on Linux for example, and have SAS HBA and a cable to connect your host with the expander. (A) Show the device for AIC Expander Controller (canister) $ sg_map -i /dev/sg2 AIC 12G 4U60swap: Hub...
  • Page 68 Clearing both bits disables the enclosure alarm. We use the software package "sg3_utils" on Linux for example, and have a SAS HBA and a cable to connect your host with the expander. (A) Show the device for AIC Expander Controller (canister) $ sg_map -i /dev/sg2 AIC 12G 4U60swap: Hub...
  • Page 69 We use the software package "sg3_utils" on Linux for example, and have a SAS HBA and a cable to connect your host with the expander. (A) Show the device for AIC Expander Controller (canister) $ sg_map -i /dev/sg2 AIC 12G 4U60swap: Hub 0c07 (B) Set "RQST IDENT"...
  • Page 70 J4060-03 User Manual Chapter 3. Sub-system Configuration Setup REQUESTED SPEED CODE 100% Leave at current speed...
  • Page 71: Chapter 4. Bios Configuration Settings

    Chapter 4. BIOS Configuration Settings J4060-03 User Manual Chapter 4. BMC Configuration Settings 4.1 Login Open a web browser and enter the default IP http://192�168�11�11� When the login window appears, set the user name and password to ''admin.'' Click Log In to continue. Type the default account and password Account:admin Password:admin...
  • Page 72: 4�2 Sensor's :Pcation For Fan & Temperature

    J4060-03 User Manual Chapter 4. BMC Configuration Settings 4�2 Sensor's :pcation for Fan & Temperature EXP: expander chip...
  • Page 73: 4�3 Utility Setup On Host

    J4060-03 User Manual Chapter 4. BMC Configuration Settings 4�3 Utility Setup on Host Please refer to Section 3.2. 4�4 Connect Host to BMC by RS232 1. Type in “[” and the screen will automatically display the IPMI serial interface. Type in the command "#[sys pwd –u admin admin ]" for logging in the interface. The screen will automatically display [OK].
  • Page 74 J4060-03 User Manual Chapter 4. BMC Configuration Settings 2. Get LAN information Get LAN static IP /DHCP [30 00 02 01 04 00 00 ] Get LAN IP [30 00 02 01 03 00 00 ] Get submask [30 00 02 01 06 00 00 ] Get gateway [30 00 02 01 0C 00 00 ] Get LAN static IP /DHCP: 01 represents static IP, 02 represents DHCP.
  • Page 75 J4060-03 User Manual Chapter 4. BMC Configuration Settings 3. Set LAN information Set LAN information Set LAN static IP /DHCP [30 00 01 01 04 01/02 ] Set LAN IP [30 00 01 01 03 C0 A8 00 0A ] Set submask [30 00 01 01 06 FF FF FF 00 ] Set gateway...
  • Page 76: Bmc Led Signal

    J4060-03 User Manual Chapter 4. BMC Configuration Settings 4.5 BMC LED Signal The are two BMD LED signals under the BMC console port. Blue LED Light- Normal execution. Red LED Light- An error occurred while executing.     BMC LAN port BMC console port BMC LAN port BMC console port...
  • Page 77: 4�6 Web

    J4060-03 User Manual Chapter 4. BMC Configuration Settings 4�6 Web UI 4�6�1 Dashboard Device Information Displays the Firmware Revision and Firmware Build Time (Date and Time). Network Information Shows network settings for the device. Click on the link Edit to view the Network Settings Page.
  • Page 78: Fru Information

    J4060-03 User Manual Chapter 4. BMC Configuration Settings 4�6�2 FRU information This page displays the BMC FRU file information. On selecting a particular FRU Device ID, the corresponding FRU information will be displayed. Basic Information It displays the FRU device ID and device name for the selected FRU device ID. Chassis Information •...
  • Page 79: Hard Disk Status

    J4060-03 User Manual Chapter 4. BMC Configuration Settings 4�6�3 Hard Disk Status This page displays all the HDD power on/off status, using the "Power On" and "Power Off" button to control HDD status. ACTIONS Power On Select the HDD to turn the power on. Power off Select the HDD to turn the power off.
  • Page 80: Storage Health

    J4060-03 User Manual Chapter 4. BMC Configuration Settings 4.6.4 Storage Health 4.6.4.1 Sensor Readings A list of sensor readings will be displayed here. Click on the record to check for more information about different sensors, such as thresholds and graphical representations of all associated events.
  • Page 81 J4060-03 User Manual Chapter 4. BMC Configuration Settings 4.6.4.2 Event Log This page displays the list of events incurred by different sensors on this device. Double click on the record to see the details of that entry. Sort the list of entries by clicking on any of the column headers.
  • Page 82: Configuration

    J4060-03 User Manual Chapter 4. BMC Configuration Settings 4.6.5 Configuration 4.6.5.1 DNS This page is used to configure the Host name and Domain Name Server configuration of the device. Host configuration Host Settings Select either Automatic or Manual settings. Host Name It displays the hostname of the device if Auto is selected. If the Host setting is selected as Manual, specify the hostname of the device.
  • Page 83 J4060-03 User Manual Chapter 4. BMC Configuration Settings Domain Name Server It contains a database of the public addresses and their associated hostnames. DNS Server Settings It lists the options for the DNS interface, Manual and available LAN interfaces. IP Priority If the IP Priority is IPv4, it will have 2 IPv4 DNS servers and 1 IPv6 DNS server. If the IP Priority is IPv6, it will have 2 IPv6 DNS servers and 1 IPv4 DNS server.
  • Page 84 J4060-03 User Manual Chapter 4. BMC Configuration Settings 4.6.5.2 Network This page is used to configure the network settings for available LAN channels. LAN Interface Select the LAN interface to be configured. LAN Settings Check this option to enable LAN support for the selected interface. MAC Address This field displays the MAC address of the selected interface (read only).
  • Page 85 J4060-03 User Manual Chapter 4. BMC Configuration Settings If DHCP is disabled, specify a static IPv4 address, Subnet Mask and Default Gateway to be configured for the selected interface. • An IP Address consists of 4 sets of numbers separated by dots as in “xxx.xxx.xxx.xxx”.
  • Page 86 J4060-03 User Manual Chapter 4. BMC Configuration Settings 4.6.5.3 Network Link This page is used to configure the network link option for the available network interfaces. LAN Interface Select the network interface from the list for which the Link speed and duplex mode are to be configured.
  • Page 87 J4060-03 User Manual Chapter 4. BMC Configuration Settings 4.6.5.4 NTP This page displays the device’s current Date & Time Settings. It can be used to configure either Date & Time or NTP (Network Time Protocol) server settings for the device. Date Specify the current Date for the device.
  • Page 88 J4060-03 User Manual Chapter 4. BMC Configuration Settings UTC Offset UTC Offset list contains the UTC offset values for the NTP server, which can be used to display the exact local time. NOTE Use the correct UTC offset after adjusting for DST automatically synchronize. Check this option to automatically synchronize Date and Time with the NTP Server.
  • Page 89 J4060-03 User Manual Chapter 4. BMC Configuration Settings 4.6.5.5 PEF This page is used to configure the Event Filter, Alert Policy and LAN Destination. To view the page, the user must at least be an Operator. To modify or add a PEF, the user must be an Administrator.
  • Page 90 J4060-03 User Manual Chapter 4. BMC Configuration Settings Send Test Alert Select a configured slot in the LAN Destination tab and click ‘Send Test Alert’ to send a sample alert to the configured destination. NOTE Test alerts can be sent only with SMTP Configurations set to enabled. SMTP support can be enabled under Configuration SMTP.
  • Page 91 J4060-03 User Manual Chapter 4. BMC Configuration Settings 4.6.5.6 SMTP This page is used to configure the SMTP settings. LAN Channel Number Select the LAN channel to which the SMTP information needs to be configured. Sender Address Enter the ‘Sender Address’ valid on the SMTP Server. Machine Name Enter the ‘Machine Name’...
  • Page 92 J4060-03 User Manual Chapter 4. BMC Configuration Settings SMTP Server requires Authentication Check the option ‘Enable’ to enable SMTP Authentication. NOTE SMTP server authentication types supported are • CRAM-MDS • Login • Plain IF the SMTP server does not support any one of the above authentication types. The user will get an error message stating, "Authentication type is not supported by SMTP server."...
  • Page 93 J4060-03 User Manual Chapter 4. BMC Configuration Settings 4.6.5.7 Schedule This page displays the device's current date & time. It can be used to configure dates within a week or specific a date to power on/off the device. If you want to change the device date & time, please go to the NTP page.
  • Page 94 J4060-03 User Manual Chapter 4. BMC Configuration Settings ACTIONS Enable schedule Check this option for enable/disable the schedule. Action Check a action to do power on/off for the device. Set days for action Setting dates within a week to do power on/off for the device. Date Specify a date for the device.
  • Page 95 J4060-03 User Manual Chapter 4. BMC Configuration Settings 4.6.5.8 User The displayed table shows any configured Users and available slots. You can modify or add new users from here. A maximum of 10 slots are available, including the default admin and anonymous.
  • Page 96: Remote Control

    J4060-03 User Manual Chapter 4. BMC Configuration Settings 4�6�6 Remote Control 4.6.6.1 Storage power control This page helps you to view or perform any host power cycle operations. Reset Expander Select an expander to do cold reset. Power Off Storage Select this option to immediately power off the storage.
  • Page 97 J4060-03 User Manual Chapter 4. BMC Configuration Settings 4.6.6.2 JAVA SOL NOTE A compatible JRE must be installed in the system prior to the launch of the JNLP file. Launch the Java SOL, you must have Administrator privileges. Choose an expander that can use smart console in Java SOL. Volatile-Bit-Rate Please set 38.4K Non-Volatile-Bit-Rate...
  • Page 98: 4�7 Firmware Update

    J4060-03 User Manual Chapter 4. BMC Configuration Settings 4�7 Firmware Update 4�7�1 Requirement Browsers: FireFox 24.0 or later version Chrome 35.0 or later version I.E. 7.0 or later version Linux: Redhat 6.4 NOTE If you want to update a new version firmware for BMC, please clear the web browser cookies when the update process is complete.
  • Page 99 J4060-03 User Manual Chapter 4. BMC Configuration Settings 3. This is login main page. 4. Click the “Firmware Update” and a drop-down menu will pop up. Click the “Firmware Update.”...
  • Page 100 J4060-03 User Manual Chapter 4. BMC Configuration Settings 5. This page will show the update warning. If you really want to update BMC firmware, click the “Enter Update Mode” button. 6. Wait few minutes, it will pop a window. Click the “Select file” to upload firmware file that you want to update.
  • Page 101 J4060-03 User Manual Chapter 4. BMC Configuration Settings 7. Wait a few minutes. it will pop a window for check update section. Check the “Check this option to do all full firmware flash” option. 8. Click “OK” for the firmware to start the update process.
  • Page 102 J4060-03 User Manual Chapter 4. BMC Configuration Settings 9. In the update process, it will take 3~5 minutes. NOTE Please do not close this web page. The firmwire will crash if you close this page. 10. When “Device has been reset” window appears, it means firmware update is successful. Wait 90 seconds for BMC to restart.
  • Page 103: 4�8 Expander Firmware Update

    J4060-03 User Manual Chapter 4. BMC Configuration Settings 4�8 Expander Firmware Update 1. Click the “Firmware Update” and it will pop a drop-down menu. Click the “Expand Update.” 2. Choose the expander firmware file that you want to update.
  • Page 104 J4060-03 User Manual Chapter 4. BMC Configuration Settings 3. Choose the expander firmware file and then click the “upload” button. 4. Click the ''Proceed'' button.
  • Page 105 J4060-03 User Manual Chapter 4. BMC Configuration Settings 5. Processing. 6. Update successful.
  • Page 106 J4060-03 User Manual Chapter 4. BMC Configuration Settings 7. If the update processes not successful, please check the version of the expander firmware or whether if the system is turned off.
  • Page 107: 4�9 Firmware Safety Mode

    J4060-03 User Manual Chapter 4. BMC Configuration Settings 4�9 Firmware Safety Mode If your update process fails or the primary firmware suffers some error, it will boot into safety mode. 1. If you see the sensor name, status LED and ID LED are abnormal, the LEDs are cross blinking, it means the firmware is in safety mode.
  • Page 108 J4060-03 User Manual Chapter 4. BMC Configuration Settings     BMC LAN port BMC console port BMC LAN port BMC console port...
  • Page 109 J4060-03 User Manual Chapter 4. BMC Configuration Settings 2. Please clear browser cookies and re-start browser. The BMC web UI will refresh the web page object.
  • Page 110 J4060-03 User Manual Chapter 4. BMC Configuration Settings 3. Click the “BMC Reset” button to go into the reset page. 4. Select the “BMC reset” and Click the “Perform Action” button.
  • Page 111 J4060-03 User Manual Chapter 4. BMC Configuration Settings 5. The page will show “Requesting” status. This web page will be invalid because of resetting the BMC. Wait 90 seconds to clear browser cookies to re-login the web UI again. 6. If you still see the safety mode page, please follow section 4.5 web update to update your firmware.
  • Page 112: Chapter 4� Technical Support

    Chapter 4� Technical Support Taiwain, Global Headquarters South California, United States Address: No. 152, Section 4, Address: 21808 Garcia Lane Linghang N. Rd, Dayuan District, City of Industry, CA 91789, Taoyuan City 337, Taiwan United States Tel: +886-3-433-9188 Toll free: +7-4997019998 Fax: +886-3-287-1818 Tel: +1-909-895-8989 Sales Email: sales@aicipc�com�tw...