Figure 2-1. Installation Clearances and
Weather Cover Dimensions
VERTICAL
AXIS
Minimum Swing
Clearance
34 in. (863 mm)
From Flange Center
PLATFORM
*Note 1:
**Note 2:
12.250 in.
R
(311 mm)
6 to 8 in.
(152 to 203 mm)
Leave 3 in.
(76 mm)
clearance from
flange face
for swinging.
TRANSCEIVER
(1524 mm)
Optional Weather
Cover
The top view represents the transceiver and retro reflector assemblies
with their swing clearances. Optional weather covers are not shown.
The side view represents the installation and swing clearance
dimensions for the optional weather covers.
6.125 in.
(156 mm)
TOP VIEW *
SIDE VIEW **
Cover In Upright Position
GAS FLOW
60 in.
OPM 4000
R 7.5 in.
(191 mm)
6.125 (156 mm)
6 to 8 in.
(152 to 203 mm)
Stack or Breeching
Wall OD
21.00 in. (533 mm)
(2) Covers
RETRO
30.5 (775 mm)
(3) Covers
Optional Weather
Cover
PLATFORM