Operators SHALL NOT use Eye Bolts (see
Meter flange tapped holes to aid in lifting or maneuvering the unit.
Operators SHALL NOT use other Hoist Rings that do not fully seat flush with the counter
bore on the top of the meter flanges.
Figure 2-6: Meter end flange with tapped flat-counterbore hole for hoist ring
A. Plug Bolt
B. Flat Counterbore Surface
Figure 2-7: Safety approved hoist ring and non-compliant eye bolt
Safety precautions using safety engineered swivel hoist
rings
Read and follow the Safety Precautions listed below:
Procedure
1. Meters must only be lifted by personnel properly trained in the safe practices of
2. Remove the plug bolts installed in the tapped holes on the top of the flanges. Do
3. Ensure the tapped holes on the meter are clean and free of debris before installing
Installation manual
rigging and lifting.
not discard the bolts as they must be reinstalled once the lifting operation is
complete to prevent corrosion of the tapped holes.
the hoist rings.
Figure
2-7) in the Daniel 3814 Liquid Ultrasonic
Mechanical Installation
May 2019