SORG Boogie Drive User Manual

Hide thumbs Also See for Boogie Drive:
Table of Contents

Advertisement

User Manual
Boogie
Drive
User Manual
1

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Boogie Drive and is the answer not in the manual?

Questions and answers

Summary of Contents for SORG Boogie Drive

  • Page 1 User Manual Boogie Drive User Manual...
  • Page 2: Revision Status

    We are a member of rehaKIND e.V. International association child and adolescent rehabilitation COPYRIGHT © by SORG Rollstuhltechnik GmbH + Co. KG Benzstraße 3-5, 68794 Oberhausen-Rheinhausen. All texts and pictures in this user manual underlie the international copyright protection and are not allowed to be published without our consent –...
  • Page 3: Table Of Contents

    SIGNS AND SYMBOLS 3.10.2 Adjusting the shear angle INDICATION 3.10.3 Adjusting the height .310.4 Adjusting the depth COUNTER INDICATION 3.10.5 Adjusting the distance SPECIFICATION BOOGIE DRIVE 3.11 WHEEL LOCK BASIC EQUIPMENT 3.11.1 Drum brake APPLICATION 3.11.2 Displacing the brake control lever RECEPTION 3.11.3 Back casters with locking lever...
  • Page 4 Boogie Drive...
  • Page 5: Overview Mobile Standing Device

    User Manual OVERVIEW MOBILE STANDING DEVICE chest truss pad therapy table toy box crank for posterior truss pad with swivel bracket side posterior truss pad centre column frame drum brake nob profile wheel 10. built in hand rim 11. side chest truss pad 12.
  • Page 6: Preamble

    THE USE MUST THEN BE STOPPED IMMEDIATELY. handling of the mobile standing device as well as the safety instructions before it is first used. Furthermore, Boogie Drive is counter indicated by: • severe impaired perception and sense of balance, If you have any questions your medical supply store or our •...
  • Page 7: Specification Boogie Drive

    SPECIFICATION BOOGIE DRIVE 1.7 BASICS TO ALL ADJUSTMENT WORK ON THE MOBILE STANDING DEVICE Boogie Drive is a mobile standing device with a centre column, which can be adjusted steplessly with a gas ATTENTION pressure spring or set mechanically with a telescope 15°...
  • Page 8: Reception

    Boogie Drive 1.10 DOCUMENTATION ATTENTION The user can never be left alone in the aid. � INDICATION Keep this user manual in a safe place. Have all work/ ATTENTION repairs done on your wheelchair documented by the The mobile standing device can not be used with faulty, medical supply store in the maintenance plan.
  • Page 9: Safety Instructions

    User Manual SAFETY INSTRUCTIONS DANGER OF TIPPING AND FLIP- PING OVER GENERAL INDICATIONS ATTENTION ATTENTION The danger of tipping and flipping over can occur from all BEFORE THE FIRST USE OF THE MOBILE STANDING DE- forms of height differences (steps, doorways, stairs) as VICE, THE CENTRE COLUMN, THE WHEELS, THE FOOT well as leaning out to the side and/or back of the mobile PLATES, THE KNEE, POSTERIOR AND CHEST TRUSS PADS...
  • Page 10: Handling And Fine Adjustments Actively Getting In And Out

    Boogie Drive HANDLING AND FINE ADJUST- MENTS ACTIVELY GETTING IN AND OUT ATTENTION WITH EVERY TRANSFRER IN/OUT OF THE MOBILE STANDING DEVICE, AN EXPERIENCED CARER MUST BE THERE TO ASSIST. EACH TRANSFER CAN ONLY TAKE PLACE ON FIRM, EVEN GROUNDS AND WITH ACTIVATED WHEEL LOCK WITH THE MOBILE STANDING DEVICE AS WELL AS WITH THE WHEELCHAIR.
  • Page 11: Actively Getting Out With Posterior Truss Pad With Additional Standing Support

    THE STAR KNOB SCREW MUST BE SCREWED ON TIGHTLY IN BOTH VERSIONS OF THE POSTERIOR TRUSS PADS. THE LATCH ALONE IS NOT ENOUGH FOR STABILISATION! THE BOOGIE DRIVE IS NOT OPERABLE WITHOUT A FIRM FIT OF THE STAR KNOB SCREWS.
  • Page 12: Actively Getting Out With Posterior Truss Pad With Crank And Swivel Bracket

    Boogie Drive 3.1.4 Actively getting out with posterior truss Setting the depth of the posterior truss pad • (1) Your carer puts the posterior truss pad in the pad with crank and swivel bracket square tube (D), until the latch (B) snaps into the...
  • Page 13: Centre Column

    User Manual CENTRE COLUMN Setting the angle of the centre column ATTENTION THE ANGLE SETTING OF THE CENTRE COLUM WITH TELESCOPE AND CLAMP LEVER CAN ONLY BE CARRIED OUT WHEN A PATIENT IS IN THE AID. Adjusting the angle of the centre column ATTENTION (3) IN ORDER TO ADJUST THE CENTRE COLUMN YOU MUST HOLD THE PATIEND AND/OR THE CENTRE CO-...
  • Page 14: Back Truss Pads

    Boogie Drive BACK TRUSS PADS (1) Height adjustment of the back truss pad: • Open the clamp lever (A) of the posterior truss pads so far that you can push the beam (B) of the back truss pad in the holder (C) freely up or down.
  • Page 15: Pelvic Truss Pads

    User Manual PELVIC TRUSS PADS INFORMATION Die Pelotten können wahlweise mit Stellschrauben oder Klemmhebel ausgestattet sein. Im Folgenden wird der Einstellvorgang anhand des je- weils benutzten Bildes beschrieben. Sollte Ihr Stehfahrer anders ausgestattet sein, verfahren Sie bitte sinngemäß. 3.8.1 Height adjustment (1) To adjust the height: •...
  • Page 16: Standard Knee Truss Pads

    Boogie Drive STANDARD KNEE TRUSS PADS ATTENTION THE KNEE TRUSS PADS MUST HAVE BEEN SET TO THE INDIVIDUAL MEASUREMENTS OF THE CHILD/ ADOLESCENT AS EXACT AS POSSIBLE BEFORE THE FIRST USE OF THE MOBILE STANDING DEVICE. WHEN THE USER IS STANDING IN THE MOBILE STANDING DEVICE, ONLY FINE ADJUSTMENTS ARE THEN ALLOWED TO BE MADE.
  • Page 17: Knee Truss Pads With Resting Brackets

    User Manual 3.10 KNEE TRUSS PADS WITH RESTING BRACKETS ATTENTION THE KNEE TRUSS PAD MUST HAVE BEEN SET TO THE INDIVIDUAL MEASUREMENTS OF THE CHILD/ ADOLESCENT AS EXACT AS POSSIBLE BEFORE THE FIRST USE OF THE MOBILE STANDING DEVICE. WHEN THE USER IS STANDING IN THE MOBILE STANDING DEVICE, ONLY FINE ADJUSTMENTS ARE THEN ALLOWED TO BE MADE.
  • Page 18: Wheel Lock

    Boogie Drive 3.11 WHEEL LOCK 3.11.1 Drum brake Normally the control lever of the drum brake is attached to the therapy table. To lock/unlock the drum brake: (1+2) Depending on the position of the control lever, in • order to lock the drum brake, pull the brake lever (A) up so far until the small locking lever (B) snaps into the groove (C).
  • Page 19: Wheels

    User Manual 3.12 WHEELS 3.12.1 Driving wheels • (1+2) To loosen or apply the quick release axle push the locking knob (A) in the middle of the hub and release it after. • (3) After application, the locking ball (A) should stick out visualy at the end of the quick release axle fitting (B).
  • Page 20: Therapy Table

    Boogie Drive 3.14 THERAPY TABLE The therapy table is attached to the centre column ex works (standard assembly). However, it can be varied in height and also attached to the chest truss pad holder. 3.14.1 Standard mounting on the centre column (1) To adjust the height: •...
  • Page 21: Repairs And Maintenance

    User Manual REPAIRS AND MAINTENANCE � INDICATION The use of a high-pressure cleaner is not allowed! REPAIRS CUSHIONS AND COVERS ATTENTION The covers of the seat and back cushions as well as the All safety relevant repairs and maintenance work are to seat and back units can be washed in the washing machine be conducted by your specialised retailer.
  • Page 22: Service List

    Boogie Drive 4.7.2 Service list The following service list is based on our long-term experience and is a mandatory guideline with which you can keep your wheelchair –possibly for a long time – in a safe-to-use condition. However, it does not give information about the extent of service or repair needed and observed on the aid.
  • Page 23: Check List Yearly Inspection

    User Manual 4.7.3 Check list yearly inspection PREPARATORY WORK We recommend, cleaning the wheelchair or individual parts of it prior to inspection. VISUAL INSPECTION Check frame, mounting parts and accessories for damage, defects in paint work and corrosion. GENERAL INSPECTION Check all fixing screws for firm fit and retighten them if necessary.
  • Page 24: Documentation Yearly Inspection

    Boogie Drive 4.7.4 Documentation yearly inspection work done date, signature, stamp medical supply store...
  • Page 25: Technical Data

    ±5° Abbreviations: FW = Frame Width AIN = Aid Index Number Data Model: Boogie Drive AIN.: 28.29.01.3010 (according to the AIN, the mobile standing device must be mounted with foot shells) Type: Type label on the frame crossbar...
  • Page 26: Meaning Of Labels

    CE sign capacity year of manufacture DECLARATION OF CONFORMITY SORG Rollstuhltechnik GmbH & Co.KG Benzstraße 3-5 D-68794 Oberhausen-Rheinhausen Tel.: +49 7254 9279-0 Fax: +49 7254 9279-10 e-mail: info@sorgrollstuhltechnik.de Web: www.sorgrollstuhltechnik.de declares with this in sole responsibility, that the following aid BOOGIE DRIVE Type Nr.: 884 (size I to III)
  • Page 27: Retailer Verification

    User Manual 4.10 RETAILER VERIFICATION • This aid has been delivered by the following retailer: SORG Rollstuhltechnik GmbH + Co. KG Benzstraße 3-5 D-68794 Oberhausen-Rheinhn. Tel +49 7254-9279.0 Fax +49 7254-9279.10 info@sorgrollstuhltechnik.de www.sorgrollstuhltechnik.de Technical changes and misprints reserved...

Table of Contents