Assembly and operating instructions
REMKO SLE series
Pool dehumidifiers
SLE 40, SLE 60, SLE 80
Read the instructions prior to performing any task!
Edition GB - N11

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the SLE Series and is the answer not in the manual?

Questions and answers

Summary of Contents for REMKO SLE Series

  • Page 1 Assembly and operating instructions REMKO SLE series Pool dehumidifiers SLE 40, SLE 60, SLE 80 Read the instructions prior to performing any task! Edition GB - N11...
  • Page 3: Table Of Contents

    Contents Dehumidification Safety information Unit description Installation Commissioning Care and maintenance Troubleshooting Refrigeration circuit Electrical wiring diagram SLE 40-80 Diagram of unit SLE 40-80 Spare parts list SLE 40-80 Maintenance log Intended use Customer service and warranty Environmental protection and recycling Unit dimensions Technical data This operating manual is a translation of the German original.
  • Page 4: Dehumidification

    REMKO SLE series Dehumidification The interrelated processes occur- In terms of energy consumption, ring during dehumidification are dehumidification has one decisive based on physical laws. advantage: These are illustrated here in simpli- fied form in order to explain the Energy expenditure is restricted principle of dehumidification.
  • Page 5 90-190 l/m³, heavy through the REMKO dehu- and the relative humidity increases. concrete 140-190 l/m³, lime-sand midifier. It is dehumidified and If the temperature falls further, the bricks 180-270 l/m³.
  • Page 6: Safety Information

    REMKO SLE series Heat of condensation The energy transferred from the Vice versa, energy is released during lated, which is consumed during condenser to the air is composed the liquefaction of gas, which is evaporation and released during termed heat of condensation.
  • Page 7: Unit Description

    Unit description The units are designed for univer- Operation sal and problem-free dehumidifica- tion. All units are switched on and off Depending on the room air tem- They can be installed at numerous by the integrated hygrostat. perature and relative humidity or locations due to their compact size.
  • Page 8: Installation

    REMKO SLE series Installation Access to control The unit should not be installed ■ ATTENTION close to radiators or other heat After removing 2 screws at the A installation of the unites are sources. top of the unit, lift up the front...
  • Page 9: Commissioning

    Commissioning Prior to each commissioning or as LED display required, the air inlet and outlet grilles must be checked for clog- ging. A constant „green“ lightning The units operate via an integrated symbol indicates that the supply is hygrostat set to 60% relative hu- The units are provided with an connected to the unit.
  • Page 10: Care And Maintenance

    REMKO SLE series Care and maintenance Fan control Cleaning the suction filter NOTE Regular care and maintenance When the hygrostat starts the The suction filter should be is a basic precondition for a dehumidifier, the fan(s) is/are checked at regular intervals and...
  • Page 11: Troubleshooting

    Troubleshooting Fault Possible cause Remedy • The unit does not start. No supply voltage. • Indicates that the unit is operating, but has switched off due to over- • Lightning symbol in display does heating. not light. • The unit does not start. Room humidity too low.
  • Page 12: Refrigeration Circuit

    REMKO SLE series Refrigeration circuit SLE 40 Legend: 1. Compressor 2. Evaporator 3. Condenser 4. Thermal expansion valve 5. Dry filter 6. Solenoid valve 7. Fan SLE 60 and SLE 80 Legend: 1. Compressor 2. Evaporator 3. Condenser 4. Thermal expansion valve 5.
  • Page 13 Electrical wiring diagram SLE 40 - SLE 80 Electronic control board Fan motors: SLE 40 = Motor M2 SLE 60 = Motor M2 and M3 SLE 80 = Motor M2, M3 and M4 Legend: Constant ventilation: External hygrostat (accessories): If constant air circulation is re- Remove the both jumper at the = Electr.
  • Page 14: Diagram Of Unit Sle

    REMKO SLE series Diagram of unit SLE 40 - 80 Fig. REMKO SLE 80 We reserve the right to make dimensional and design changes in the interest of technical advances.
  • Page 15: Spare Parts List Sle

    Spare parts list Designation SLE 40 SLE 60 SLE 80 EDP No. EDP No. EDP No. Wall bracket 1109144 1109165 1109177 Housing rear 1109145 1109166 1109178 Cable gland 1109129 1109129 1109129 Condenser 1109146 1109167 1109179 Fan complete with 800mm cable 1109147 1109147 1109147...
  • Page 16: Maintenance Log

    REMKO SLE series ✍ Maintenance log Model: ........Serial No.: ........10 11 12 13 14 15 16 17 18 19 20 Unit cleaned - externally Unit cleaned - internally Condenser cleaned Evaporator cleaned Fan function checked Unit checked for damage...
  • Page 17: Intended Use

    “Warranty Docu- Think of the environment when The manufacturer is not liable for ment” to REMKO GmbH & Co. disposing of the packaging mate- any damage attributed to failure KG at the time of sale and com- rial.
  • Page 18: Unit Dimensions

    REMKO SLE series Unit dimensions Series Dimensions in mm SLE 40 SLE 60 1260 1190 SLE 80 1800 1730 Maß- und Konstruktionsänderungen, die dem technischen Fortschritt dienen, bleiben uns vorbehalten.
  • Page 19: Technical Data

    Technical Data Series SLE 40 SLE 60 SLE 80 Daily dehumidification capacity at 30°C and 80% Litre/day 50.4 70.8 100.8 relative humidity Daily dehumidification capacity at 30°C and 60% Litre/day 32.2 43.2 64.0 relative humidity Operating temperature range °C 10 to 36 Humidity operating range % rel.
  • Page 20 REMKO SLE series Capacity diagram SLE 40 40% r.F. 60% r.F. 80% r.F. Dehumidification capacity [l/h] Capacity diagram SLE 60 40% r.F. 60% r.F. 80% r.F. Dehumidification capacity [l/h]...
  • Page 21 Capacity diagram SLE 80 40% r.F. 60% r.F. 80% r.F. Dehumidification capacity [l/h]...
  • Page 22 REMKO SLE series...
  • Page 24 SFlb Customer Service Our equipment operates precisely and reliably. However, in the event of a fault, REMKO customer service is quickly at REMKO GmbH & Co. KG the scene. Our comprehensive Air conditioning and heating technology network of experienced dealers...