Transportation Care and maintenance Troubleshooting Electrical wiring diagram Exploded view of the AMT 45-E unit Spare parts list AMT 45-E Exploded view of the AMT 65-E and 85-E units Spare parts list AMT 65-E and 85-E Exploded view of the AMT 115-E unit...
The mechanical heat that is released by The use of the dehumidification process is fed REMKO air dehumidifiers back into the room. – Even if windows and doors Under normal use, the air are well insulated, water and...
Page 5
REMKO air dehumidifier. relative humidity increases. such as brick 90-190 l/m³, heavy The air is dehumidified and, If the temperature continues to fall, concrete 140-190 l/m³...
REMKO AMT Condensation heat The Energy transferred to the air but is required to convert a liquid whereby heat is consumed from the condenser consists of: into a gas. for evaporation and released Conversely, energy is released for condensation. 1. the amount of heat derived when gas is liquefied, this is beforehand in the evaporator.
"certificate of material, please consider our structural design and equipment. guarantee" to REMKO GmbH & environment. Co. KG at the time when the units Our units are carefully packed The units must only be operated are purchased and commissioned.
The units are used in all locations, where dry air is a must and where Schematic depiction of the workings of a REMKO air dehumidifier economic consequential damage (such as that caused by mould) must be prevented.
Set-up For the best economic and safe use Avoid having opened windows Electrical connection ■ of the units, the following notes and doors etc., and avoid must be followed in full: frequent entry to or exit from The units are operated ■...
Operation with a humidity local requirements dictate, the air- switch inlet grille and air-outlet grille must be checked for contamination. The REMKO humidity switch (accessories) is supplied with a special adapter. NOTE The following procedure must A contaminated grille or filter...
Page 11
10 seconds. In the AMT 45-E, the hose is The unit will switch off and connected directly to the ½" the yellow indicator light connection nozzle [D] of on the control panel will illuminate.
REMKO AMT Shutdown AMT 115-E condensate drain Move the operating switch Due to their high dehumidification capacity, the AMT 115-E units are not to the "0" (off) position. equipped with an internal condensate container. The condensate drainage is to be provided by the customer in suitable containers via the exterior unit connection nozzles (½").
Transportation Care and maintenance For easy transportation, the units Cleaning the dust filter NOTE are equipped with 2 large Regular care and maintenance wheels and an ergonomic ATTENTION is fundamental to a long transportation and protective Check the inlet and outlet grille service life and fault-free clamp.
REMKO AMT Cleaning the units 9. Once cleaning has been The red indicator light completed, the unit should be (Malfunction) illuminates The unit housing must be opened dried. Take particular care with to allow the inside of the unit to be...
Electrical wiring diagram AMT 45-E to 115-E Control board Lamp Operating Compressor Changeover Ambiente Probe °C Probe °C Probe °C water Fail hours valve air fan evaporator condenser water stop stop lamp Yellow Not applicable for AMT 115-E Compressor Fan motor...
REMKO AMT Exploded view of the AMT 45-E unit 32 33 We reserve the right to modify the dimensions and design as part of the ongoing technical development process.
REMKO AMT Exploded view of the AMT 65-E and 85-E units We reserve the right to modify the dimensions and design as part of the ongoing technical development process.
Spare parts list for the AMT 65-E and 85-E units Description AMT 65-E AMT 85-E EDP no. EDP no. Air-inlet grille 1105659 1105659 Dust filter 1105660 1105660 Fixed base cpl. 1105661 1105661 Transportation bracket 1105662 1105662 Evaporator fin package cpl. 1105711 1105731 NTC evaporator probe...
REMKO AMT Exploded view of the AMT 115-E unit We reserve the right to modify the dimensions and design as part of the ongoing technical development process.
Technical data Series AMT 45-E AMT 65-E AMT 85-E AMT 115-E Operating range, temperature °C 3-32 3-32 3-32 3-32 Operating range, humidity % RH 40-100 40-100 40-100 40-100 Dehumidification capacity max. l/day at 30°C/80% RH l/day (DER) 37.4 (2.32) 56.8 (2.96) 70.8 (3.07) 106.4 (3.47) at 20°C/70% RH...
Page 24
REMKO, a partner who helps to solve problems. Sales REMKO offers not just a well- established sales network both nationally and internationally, but also has exceptionally highly- qualified sales specialists. REMKO employees in the field...