  • Page 1 REMKO ASF 100 Portable dehumidifier with adsorption rotor Operation · Technology · Spare parts Edition GB – T12...
  • Page 3: Table Of Contents

    These operating instructions must be read carefully before commissioning/using the unit! These instructions are part of the unit and must always be kept near to the site of installation or on the unit. Made by REMKO Subject to changes; errors and typographical errors excepted!
  • Page 4: Unit Description

    REMKO ASF 100 Unit description The units are designed for Operation universal and problem-free dehumidification. The units can be switched on and room air through the unit, the off with the ON/OFF button. relative humidity in the room is Owing to their compact size, they...
  • Page 5: Installation

    ■ in the immediate vicinity of into account. radiators or other heat sources. Diagram showing installation of the REMKO dehumidifier ATTENTION All extension cables must only be used uncoiled. ATTENTION The unit must not be discon-...
  • Page 6: Safety Information

    REMKO ASF 100 Safety information Commissioning The units were subjected to ex- Prior to each commissioning Control panel tensive material, functional and or as required, the air inlet and quality inspections and tests prior outlet grilles must be checked for The control panel contains control to delivery.
  • Page 7 Unit commissioning NORMAL POWERFUL This is the comfort mode. 1. Connect the units The unit regulates according to This is the most powerful mode. to a properly fused time (12 hours) or on reaching power socket. the preset humidity, the dehu- midification capacity and fan relative humidity 45 –...
  • Page 8 REMKO ASF 100 Empty condensate container IONISER The unit has an ioniser genera- The installed condensate container 3. Carefully place the emptied con- tor for the generation of negative must be emptied from time to densate container with closed ions.
  • Page 9: Decommissioning

    Decommissioning Unit transport 1. Remove the cover [F] from Switch off the unit with The units are provided with a the rear wall of the unit with a the ON/OFF button on handle for easy and convenient suitable tool. the control panel. transport.
  • Page 10: Care And Maintenance

    REMKO ASF 100 Care and maintenance Filter cleaning NOTE Regular care and maintenance The unit is provided with an inte- 4. Clean the air inlet grille with is a basic precondition for a grated air filter to prevent damage. warm water or a vacuum long useful life and trouble- cleaner.
  • Page 11: Troubleshooting

    Troubleshooting Cleaning internal components The units were manufactured us- The unit operates, but with ing the latest production methods no condensate formation: and tested repeatedly for perfect NOTE function. Check the room temperature ■ Only authorised specialists The operating range of the unit may carry out adjustments and If faults should still occur, the unit is between 1°C and 40°C...
  • Page 12: Intended Use

    Think of the environment when The units must not be used for any returned the enclosed “Warranty disposing of the packaging other purposes. document” to REMKO GmbH & material. Co. KG. Our units are carefully packed for The units must only be operated...
  • Page 13: Maintenance Report

    ✍ Maintenance report Type of unit: ........Serial number: ........10 11 12 13 14 15 16 17 18 19 20 Unit cleaned – externally - Unit cleaned – internally - Fan blade cleaned Fan housing cleaned Condenser cleaned Adsorption rotor cleaned Fan function tested Air inlet grille with filter cleaned Unit checked for damage...
  • Page 14: Electrical Wiring Diagram

    REMKO ASF 100 Electrical wiring diagram Heating element Fin motor Control panel 230 V/1~/50Hz Transformer Output Thermostat Heating element Thermal fuse Front Heating element Miniature fuse Humidity sensor Microswitch Ioniser Transformer Thermal fuse Input Regeneration Rear circuit Heating element Adsorption...
  • Page 15: Technical Data

    Technical Data Series ASF 100 Operating temperature °C 1 bis 40 Operating humidity % r. H. 45 - 100 Max. dehumidification output l/day at 20°C/70% relative humidity l/day at 15°C/60% relative humidity l/day Max. air volume flow Condensate container capacity...