REMKO SLE 45 Operating And Installation Instructions

REMKO SLE 45 Operating And Installation Instructions

Swimming pool dehumidifiers
Hide thumbs Also See for SLE 45:

Advertisement

Quick Links

Operating and
installation instructions
REMKO SLN series
Swimming pool dehumidifiers
SLE 45, SLE 65, SLE 85
Read the instructions prior to performing any task!
Edition GB – N12

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the SLE 45 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for REMKO SLE 45

  • Page 1 Operating and installation instructions REMKO SLN series Swimming pool dehumidifiers SLE 45, SLE 65, SLE 85 Read the instructions prior to performing any task! Edition GB – N12...
  • Page 3: Table Of Contents

    Contents Safety notes Air dehumidification Testing the water quality Unit description Set-up 10-13 14-15 Commissioning Unit function Wireless remote control 17-19 LED remote control Care and maintenance Troubleshooting Fault and information messages Diagram, cooling cycle Electrical wiring diagram Intended use Customer service and guarantee Environmental protection and recycling Exploded view of the unit...
  • Page 4: Safety Notes

    REMKO SLE series Safety notes The units must not be exposed The units are only permitted ■ ■ The units have been subjected to to direct jets of water to be set up or installed in the extensive material, functional and intended position (upright) quality inspections prior to delivery.
  • Page 5: Air Dehumidification

    The mechanical heat that is released by the dehumidification The use of process is fed back into the room. REMKO air dehumidifiers Under normal use, the air – Even if windows and doors dehumidifier uses approximately are well insulated, water and...
  • Page 6 REMKO air dehumidifier. and so relative humidity increases. If the temperature continues to such as brick 90-190 l/m³, heavy The air is dehumidified and, concrete 140-190 l/m³...
  • Page 7 Condensation heat The Energy transferred to the air Conversely, energy is released When dehumidifying, a heat from the condenser consists of: when gas is liquefied, this is cycle is created, whereby heat is designated as condensation heat. consumed for evaporation and 1.
  • Page 8: Testing The Water Quality

    REMKO SLE series Testing the water quality Water quality The correct combination of chemicals in swimming pools in indoor areas is of major importance to the health of the users and for systems in the vicinity of the swimming pool and its plant room.
  • Page 9: Unit Description

    If designed as an RGB-LED, a remote control is also supplied. Schematic depiction of the workings of the SLE 45-85 air dehumidifier LED light function LED operating switch Warmed and...
  • Page 10: Set-Up

    REMKO SLE series Set-up For optimum and safe use of the The unit must be mounted or ■ Mounting the units on the wall units, the following notes must be set up upright to ensure that air followed in full:...
  • Page 11 Condensate water drain Location of the condensate drain The condensate water drain is located on the unit's base. The condensate drain is connected to the discharge nozzle supplied. A solid or flexible 3/4” discharge connector can be installed on this. The discharge hose must always ■...
  • Page 12 REMKO SLE series Installing the SLE panel with 1. Opening the connection flap LED light function To equip the unit with a panel for the LED light function, follow these instructions. 1. Open the connection flap on the bottom. 2. Connect the supplied cable section (0.5 m) with plug contact.
  • Page 13 7. Closing the connection flap 7. Re-close and fasten the connection flap. 8. Connect the unit to the power supply. 9. Remove the control board cover. 10. Set the room humidity on the control board (see commissioning). 11. Re-attach the control board cover using the two screws.
  • Page 14: Commissioning

    REMKO SLE series Commissioning Before commissioning the unit or if Control board USB interface local requirements dictate, the air- inlet grill and air-outlet grill must The units are equipped with an The information on the USB be checked for contamination.
  • Page 15 Menu structure Code: °C Code: SI The code “°C” stands for external The code “SI” stands for the To define the setpoints using the heating control with the aim of maintenance interval that the integrated operator panel, hold reaching a defined setpoint. The operator or fitter requires.
  • Page 16: Unit Function

    REMKO SLE series Unit function Fan control Compressor control LED light function If the unit was delivered with the When the control board puts the The compressor has a 6 minute dehumidifier into operation, the restart delay. The delay period...
  • Page 17: Wireless Remote Control

    The wireless remote control is intended for use with the SLE 45- 65-85 dehumidifier models. The wireless remote control has a coverage distance of up to 50 metres from the installation location of the unit.
  • Page 18 REMKO SLE series Coupling Location of the control board Connecting the antenna The antenna is located on the control board inside the unit or can be fitted there. This will be pre-installed if the unit is delivered together with the remote control.
  • Page 19 General Fitter setup menu Fault priority The wireless remote control Hold down the Right key for In the event that several faults displays the values for humidity 5 seconds to open the fitter setup occur at the same time, only the and temperature at all times.
  • Page 20: Led Remote Control

    LED wireless remote control (RGB) used to set the colour modes. The LED wireless remote control is Speed Speed intended for use with SLE 45-65- Brightness + Brightness - 85 dehumidifier models that are equipped with the RGB LED light function.
  • Page 21: Care And Maintenance

    Heavily contaminated filters thoroughly must be replaced with new parts. If the evaporator’s fins are ■ Only original REMKO spare heavily soiled, they can be parts may be used. cleaned carefully with soapy water Cleaning the condensate Never subject to direct jets of water collection tray ■...
  • Page 22: Troubleshooting

    REMKO SLE series Troubleshooting Malfunction Possible cause Remedial measures • The unit does not start. No mains voltage. • Check the power supply • The display does not light up. or fuses or switches • The LED does not illuminate.
  • Page 23: Fault And Information Messages

    Fault messages Code and Cause Remedial measures value The connection to the remote When the connection is restored, acknowledge by LOSS control has been lost clicking “OK”. Ambient temperature is not within Acknowledgement not possible. Automatic reset as soon the permissible range as the temperature has returned to the permissible range.
  • Page 24: Diagram, Cooling Cycle

    REMKO SLE series Cooling cycle SLE 45 - 85 Legend: 1. Compressor 2. Evaporator 3. Condenser 4. Thermal expansion valve 5. Dry filter 6. Solenoid valve 7. Fan We reserve the right to modify the dimensions and design as part of the ongoing technical development process.
  • Page 25: Electrical Wiring Diagram

    Legend: Fan motors: VALVE = solenoid valve FAN 1 = fan motor 1 SLE 45 = FAN 1 RUN = potential-free contact FAN 2 = fan motor 2 SLE 65 = FAN 1 and FAN 2 FAIL = potential-free contact...
  • Page 26: Intended Use

    Only high-grade materials are the written authorisation of processed, the majority of which REMKO GmbH & Co. KG . Important information are recyclable. concerning recycling You also contribute to The units are operated with...
  • Page 28: Exploded View Of The Unit

    REMKO SLE series Exploded view of the unit...
  • Page 29: Spare Parts List

    Spare parts list Designation SLE 45 SLE 65 SLE 85 Wall-mounted bracket Wall spacer Cable gland Series terminals on DIN rail Control board Holder for control board with operator panel Condenser fan Compressor capacitor Spatter guard Compressor Compressor accessories Solenoid valve...
  • Page 30: Rs-485 Interface

    REMKO SLE series RS-485 interface The RS-485 interface uses the Modbus RTU protocol as a slave unit. The unit does not have an address. Settings: 115200, N, 8, 1. It accepts queries for any address. Code functions 0x06 Present single register...
  • Page 31 Database Register Byte Min Max Description parameters Cond_temp1 (decimal) Condenser temperature: Use as described above Cond_temp1 (fraction) Aux_temp (fraction) Auxiliary probe temperature: Use as described above Aux_temp (fraction) Amb_temp (decimal) Ambient air temperature: Use as described above Amb_temp (fraction) Amb_hum Ambient air humidity: (High byte) High byte is insignificant and always contains...
  • Page 32 REMKO SLE series Database Register Byte Min Max Description parameters SW build number (high) 65535 Software build number SW build number (low) SW version Main version number of the software (Main version) SW version Minor version number of the software...
  • Page 33: Usb Interface

    USB interface The USB interface is used for transferring data logs from the unit to a USB stick. The unit data is saved every three hours and stored in the internal memory. Switching the status to fault mode also triggers the storage of data. If the memory is completely full, the oldest logs are overwritten by the newest logs.
  • Page 34: Maintenance Log

    REMKO SLE series ✍ Maintenance log Unit type: ........Unit number: ........10 11 12 13 14 15 16 17 18 19 20 Unit cleaned - outside - Unit cleaned - inside - Condenser cleaned Evaporator cleaned Fan function checked...
  • Page 35: Technical Data

    Technical data Series SLE 45 SLE 65 SLE 85 Daily dehumidification capacity at 30 and 80 % RH Litres/day Daily dehumidification capacity at 30 and 60% RH Litres/day 35.5 56.2 78.8 Operational temperature range °C 10 to 36 Usable humidity range...
  • Page 36 Die Lampen können in der The bulbs in the light cannot be replaced. Leuchte nicht ausgetauscht be replaced. Leuchte nicht ausgetauscht werden. werden. 874/2012 874/2012 Characteristic curves Capacity diagram SLE 45 40% r.F. 60% r.F. 80% r.F. Dehumidification capacity [l/h]...
  • Page 37 Capacity diagram SLE 65 40% r.F. 60% r.F. 80% r.F. Dehumidification capacity [l/h] Capacity diagram SLE 85 40% r.F. 60% r.F. 80% r.F. Dehumidification capacity [l/h]...
  • Page 38 REMKO SLE series Notes...
  • Page 40 This has given us the reputation of being more than just an excellent, reliable supplier: REMKO, a partner who helps to solve problems. Sales REMKO offers not just a well established sales network both...