10 Technical data
MaxWeb XPN
Equipment
Installation
Integrated memory
Power supply
Max. power consumption
User interface
CE-compliant
Ambient
Protection class
conditions
Temperature range for opera-
tion and storage
Functions
Languages
Energy management
Alarm
Interfaces
Communication interfaces
Communication modules
(optional)
I/Os
Weight &
Weight
Dimensions
Dimensions (WxHxD)
11 Disposal
Dispose of the data logger in compliance with the disposal regulations for electrical equip-
ment applicable at the place of installation.
Wall, top-hat rail
256 MB Flash, 256 MB DDR2 RAM
Jack socket 230 VAC/15 ... 24 VDC
24 W
Web browser with JavaScript
Yes
IP20
– 20...+ 40 ° C
German, English, French, Italian, Spanish,
Polish
Energy generation, energy consumption,
energy storage, grid feed, peak output
and operating time in the last 31 days, 12
months, 10 years.
Output curves of the last 7 days, resource
identification, consumption classification,
self-learning energy management, evalua-
tion of external factors
Multilevel, via email and/or SMS
RS485 or Ethernet
GPRS, LTE, KNX, Modbus
8 digital inputs, 4 relay outputs, 4 analogue
inputs (4-20 mA)
320 g
161 mm x 90 mm x 65 mm
en