  • Page 3 Via Benini, 1 40069 - Zola Predosa BOLOGNA - ITALY Hereby declares that: the 620, 640, 642 automation system • is intended to be incorporated into machinery, or to be assembled with other machinery to constitute machinery in compliance with the requirements of Directive 89/392 EEC, and subsequent amendments 91/368 EEC, 93/44 EEC and 93/68 EEC;...
  • Page 4: General Safety Regulations

    17) Each installation must be fitted with at least one fashing light (e.g. FAAC LAMP, MINILAMP etc) as well as a warning plate suitably fixed to the gate, besides the safety devices as per point 16. above.
  • Page 5: Description And Technical Characteristics

    ENGLISH AUTOMATION SYSTEMS 620 - 640 - 642 & 624 MPS The automation system consists of a white aluminium beam with red reflectors and of a cataphoresis treated steel housing with polyester finish. The housing contains the operator, which consists of a hydraulic power unit and two pistons.
  • Page 6: Standard Installation Layout

    (F). of the electrical cables. E.g.: The 620 rapid, 640, 642 R/40 and 642/70 operators can 2) Always route the low voltage accessory connection work continuously with a 100% duty cycle, because they cables separately from the 230 V~ power supply cables.
  • Page 7 4) Assemble the beam, using the screws supplied, as and wait for the cement to set. shown in Figures 10 and 10 b. Apply the cap to the hole (620 only). The rubber- 4.3. MECHANICAL INSTALLATION edged side of the beam must be in the closing 1) Fix the housing to the base plate using the four nuts direction.
  • Page 8 1.50 - 2.24 4.50 721085 STOP deactivated activated 2.25 - 2.74 5.50 721069 ALARM beam moving beam stationary 620 STANDARD 2.75 - 3.24 6.00 721070 620 RAPID WARN. LIGHT see warn. light operation see warn. lightoperation 3.25 - 4.00 7.30 721072 POWER...
  • Page 9: Alarm Condition

    1 2 3 4 5 6 7 8 9 10 111213 14 15 16 17 PE N L1 OPERATION OF SAFETY DEVICES FAAC LAMP 24 VAC In the A or E logics, it is possible to obtain two different MAX 5 W...
  • Page 10: Manual Operation

    ENGLISH 5.3. ADJUSTMENT OF STROKE END DECELERATION OPERATION WITH THE DIFFERENT CONTROL LOGICS 1) Position microswitch SW6 according to the amount of TAB. 7 A LOGIC (AUTOMATIC) deceleration required: impulse OFF: SHORT (1.5 sec). OPEN STOP SAFETY PANIC ON: LONG (2.5 sec). beam status For beams up to 4 m long, a short deceleration is...
  • Page 11: Returning To Normal Operation

    - Insert the standard key (Figures 19 a) or the personalised 9. REPAIRS key (Figures 19 b) in the lock and turn anticlockwise by one revolution. For repairs, contact an authorised FAAC Service Centre. - Open or close the barrier manually. 10. ACCESSORIES 7. RETURNING TO NORMAL OPERATION...
  • Page 12 IMPORTANT!If the articulation kit is fitted, the balance spring P1 = base plate for barrier P2 = base plate for support fork must be adjusted. L = beam length (in mm) A = L-425 mm (620) L- 450 mm (640)
  • Page 13 GENERAL SAFETY REGULATIONS The barrier units have safety devices (photocells) that When correctly installed and used , the 620, 640 and 642 prevent the beam from closing when they are darkened automation systems ensure a high degree of safety.