Annual
operation (mandatory)
Dissemble the flange and the heating elements (resistances and sheath)
Check the inside of the tank; descale if necessary
Change the seal
Dismantle the heating elements (resistances and sheath) and clean them
As this operation is tricky, you are strongly advised to use a specialised company.
carefully of any deposit.
Our warranty will not apply if, in the event of incident, this operation has been
neglected.
19. TROUBLESHOOTING
This appliance has been designed to give you full satisfaction. However, here are a
few examples of possible malfunctions and the related solutions.
SWITCH OFF THE POWER BEFORE ANY INTERVENTION ON THE
No hot water at all
a) The appliance has not yet worked:
First check that the safety thermostat is not activated. Press the black button
Check, using a voltmeter, that the current is reaching:
on the outside of the unit to reset it. Incident often caused by transport.
1 - the thermostat, otherwise check the circuit breaker, the fuses, the EDF
eter or a
2 - the switch, otherwise check the thermostat and its adjustment, which
may be too low.
3 - the resistances, otherwise check that the switch is not abnormally stuck
in the open position.
4 - check:
the connection of each resistance
that it corresponds to the type of current
the cabling diagram of the instructions.
5 - Lastly, replace the resistances
b) The appliance has worked before:
If the safety device is not at issue, check the power supply with a voltmeter, in the
order of points 1 to 5 above.
EN
APPLIANCE
other re ote co trol progra
34
ed to "TOP .
Document ref.: 428016 03