5.
ELECTRICAL CONNECTION
Before connecting the appliance, check that the power is off, that the appliance is full of
water and that it is watertight.
Recommendations for installation:
The electrical installation must comply with national regulations in force in the
country of installation. For France, see standards NF C 732OO and NFC 15100.
Install a general circuit breaker and calibrated protection upstream on the electrical
supply.
Use correctly sized
connections are fully tightened.
The components mentioned on the electrical diagrams are provided with the
electrical kits.
Each component and the tank must be connected to earth (via the sleeves situated
on the flange of the tank).
The resistances must be supplied using an electromagnetic switch (not provided).
Connect its electrical circuit and the loop pump using terminals C1 and C3 of the
terminal block.
Never block it manually.
Do not install manual override switches.
It must be sufficiently sized.