Single Coil Range - ACV LCA HP 2000 mh Technical Manual

Electric water heaters and enamelled heater tanks from 300 to 3000l
Table of Contents

Advertisement

10.

SINGLE COIL RANGE

This is an enamelled tank with single exchanger designed for the production of Domestic
Hot Water from a heating application such as boiler or solar panels (Operating pressure max
: 7bar).
Ø A
(L)
(mm)
B
C
300
630
1386
1055
500
630
1983
1752
750
790
1891
1601
1000
790
2244
1956
1500
1100
2073
1700
2000
1100
2261
1885
2500
1400
2136
1680
3000
1400
2269
1808
TEMP. SENSORS
Important : For the tank of 2500 and 3000L there are 3 side connections extenders in
stainless steel. These pieces are into the box of feet enhancers.
This range is fitted with both vertical anodes on the upper flange and horizontal anodes.
EN
ELEVATION (mm)
D
E
F
G
H
807
807
472
150
204
1332
1108
463
150
204
1246
1051
501
150
196
1471
1246
501
150
196
1380
1150
600
200
221
1500
1244
600
200
221
1350
1180
680
200
216
1432
1245
680
200
216
ØK
I
J
K
L
525
-
110
982
525
-
110
1615
110 or
551
704
1623
400
110 or
551
704
1929
400
110 or
650
803
1722
400
110 or
650
803
1722
400
110 or
730
883
1587
400
110 or
730
883
1587
400
2 or 3 anodes
according to
models
26
EXCHANGE
SURFACE
M
N
O
P
472
-
330
36
472
-
330
36
502
465
425
34
502
465
425
34
605
620
580
32
605
620
580
32
680
730
730
31
680
730
730
31
COIL INTLET
COIL OUTLET
DCW INLET / DRAIN
3 FEET ENHANCER
Document ref.: 428016 03
WEIGHT
WITH
INSULATION
(m²)
(kg)
1,6
127
3
177
4
256/295
5.2
326/362
5,6
458/500
5,6
489/531
7
636/678
7
658/700
DHW OUTLET

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents