9.3
Opening and Closing the Compressor Cabinet
To open:
Open the access door (1).
Pull the locking lever (3, photo A) outwards, turn 90 in the direction of the arrow and
latch onto the frame.
Lift the panel (2) and remove.
To close:
Turn the locking lever (3) to its initial position.
Attach the panel (2) making sure that it latches.
Close the access door (1).
1
1 Maintenance door
2 Cover panel
3 Unlocking lever
Maintenance
Close all maintenance doors and panels correctly before starting the
compressor package.
A
2
3
9 --- 32