REGULAR CHECKS AND MAINTENANCE WORK

EVERY 50 SERVICE HOURS

BChecking of fuel pipes and clamp bands
To avoid personal injury or death:
A Stop the engine before checking or
replacing the fuel pipes. Broken fuel
pipes can cause fires.
Check the fuel pipes every 50 hours of operation. When if;
1. If the clamp band is loose, apply oil to the screw of the
band, and tighten the band securely.
2. If the fuel pipes, made of rubber, become worn out,
replace them and clamp bands every 2 years.
3. If the fuel pipes and clamp bands are found worn or
damaged before 2 years' pass, replace or repair them
at once.
[D1803-CR-TIE4, V2403-CR-TIE4]
(1) Clamp band
(2) Fuel pipe
[V2607-CR-TIE4, V3307-CR-TIE4]
(1) Clamp band
(2) Fuel pipe
REGULAR CHECKS AND MAINTENANCE WORK
[V3800-TIE4]
(1) Clamp band
(2) Fuel pipe
BDraining of water separator
[Checking and Draining]
Water and dirt contained in fuel will settle down in the
water separator. When such foreign substances are
deposited, set the water separator handle to the
"CLOSE" position. Loosen the top screw first and then
the bottom shutoff-valve to let the foreign substances out
of the separator.
Finally be sure to air-bleed the fuel system.
[Cleaning]
1. Set the water separator handle to the "CLOSE"
position.
2. Loosen and remove the cup proper, and clean its
inside with light oil.
3. Tighten up the cup proper.
(1) Screw
(2) Cup
(3) Water separator handle
(4) Line
(5) Float
(6) Shutoff-valve