Start-up
Vitodens 200-W B2HA 112, 150, 399, 530 Service
Start-up Wizard
(continued)
Select zone circuits
During the start-up wizard an additional display screen will
come up asking for the number of connected zone circuits
use
to adjust and press OK.
If no zone circuit is selected the control will finish the
set up and display will show DHW/Heating circuit 1,
outdoor temperature, indoor temperature setup and burner
operating status.
Select zone circuit type
Each zone circuit can be operated either as a fixed
setpoint or weather compensated (using the outdoor
temperature sensor) thermostat, use
to select and
press OK.
Select fixed setpoint
For zone circuits with fixed setpoint operation select
desired supply water temperature use
to adjust and
press OK.
Adjust heating curve
Select between slope and shift with
and
to adjust
and press OK.