Tightening Torques; Cable Entries, Sealing Plugs And Thread Adapters; Connecting The Grounding Conductor - Siemens SIMOTICS DP 1PC134 Operating Instructions Manual

Low-voltage crane motors
Hide thumbs Also See for SIMOTICS DP 1PC134:
Table of Contents

Advertisement

Cable glands with connecting thread in the terminal box (EN 50262)
6.2

Tightening torques

Note the information in Chapter Tightening torques (Page 111).
6.2.1

Cable entries, sealing plugs and thread adapters

Note the following when mounting:
● Avoid damaging the cable jacket.
● Adapt the tightening torques to the cable jacket materials.
Observe the documentation for tightening torques of the cable entries and sealing plugs for
direct mounting at the machine as well as additional glands (e.g. adapters).
6.3

Connecting the grounding conductor

The machine's grounding conductor cross-section must comply with EN / IEC 60034-1.
Please also observe installation regulations such as those specified in EN / IEC 60204-1.
Basically, there are two ways of connecting a grounding conductor to the machine.
● Internal grounding with a connection in terminal box at the location intended for this purpose
and marked accordingly.
● External grounding with connection at the stator housing at the locations intended for this
purpose and marked accordingly.
1PC134, 1PC136 crane motors SH 132 ... 315
Operating Instructions, 02/2019, A5E43212221A
6.3 Connecting the grounding conductor
O ring
Electrical connection
55

Advertisement

Table of Contents
loading

This manual is also suitable for:

Simotics dp 1pc136

Table of Contents