Technical Data; Tightening Torques; Tightening Torques For Screw And Bolt Connections; B.1 Tightening Torques - Siemens SIMOTICS DP 1PC134 Operating Instructions Manual

Low-voltage crane motors
Hide thumbs Also See for SIMOTICS DP 1PC134:
Table of Contents

Advertisement

Technical data

B.1

Tightening torques

B.1.1

Tightening torques for screw and bolt connections

Bolt locking devices
● Refit nuts or bolts that are mounted together with locking, resilient, and/or force-distributing
elements with identical, fully-functional elements when re-assembling. Always renew keyed
elements.
● When screwing together threads secured with a liquid adhesive, use a suitable medium
such as Loctite 243.
● Always use suitable securing devices or removable adhesives (e.g., Loctite 243) when
installing fixing bolts with a clamping length of less than 25 mm. The clamping length is taken
as the distance between the head of the bolt and the point at which the bolt is screwed in.
Tightening torques
The bolted connections with metal contact surfaces, such as end shields, bearing cartridge
parts, terminal box parts bolted onto the stator frame, should be tightened to the following
torques, depending on the thread size:
Table B-1
Thread
Nm
The tightening torques stated above apply to screws with property class 8.8, A4-70 or A4-80
according to ISO 898-1, however only to bolts screwed into components made from materials
with the same or higher property class, e.g. cast iron, steel or cast steel.
Non-standard tightening torques
Different tightening torques for electrical connections and bolted connections for parts with flat
seals or insulating parts are specified in the relevant sections and drawings.
1PC134, 1PC136 crane motors SH 132 ... 315
Operating Instructions, 02/2019, A5E43212221A
Tightening torques for bolted connections with a tolerance of ±10 %.
M5
M6
5
8
M8
M10
M12
20
40
70
B
M16
M20
M24
170
340
600
111

Advertisement

Table of Contents
loading

This manual is also suitable for:

Simotics dp 1pc136