Basic Operations Of The Test Mode; Selecting The Test Mode - Sony HCD-C5 Service Manual

Sony stereo system user manual
Hide thumbs Also See for HCD-C5:
Table of Contents

Advertisement

HCD-C5

4. BASIC OPERATIONS OF THE TEST MODE

All operations are performed using the . "R" , > "R" , ENTER/YES "R" and MENU/NO "R" .
The functions of these buttons are as follows.
Function name
. "R" , > "R"
buttons
ENTER/YES "R" button
MENU/NO "R"
button

5. SELECTING THE TEST MODE

There are 26 types of test modes as shown below. The groups can be switched by pressing the . "R" or > "R" button.
After selecting the group to be used, press the ENTER/YES "R" button. After setting a certain group, pressing the . "R" or
> "R" button switches modes shown below.
Refer to "Group" in the table for details can be selected.
All items used for servicing can be treated using group [Service]. So be carefully not to enter other groups by mistake.
Note: Do not use the test mode in the [Develop] group.
If used, the unit may not operate normally.
If the [Develop] group is set accidentally, press the MENU/NO "R" button immediately to exit the [Develop] group.
Display
No.
AUTO CHECK
C01
Automatic self-diagnosis
Err Display
C02
Error history display, clear
TEMP ADJUST
C03
Temperature compensation offset adjustment
LDPWR ADJUST
C04
Laser power adjustment
Iop Write
C05
Iop data writing
Iop NV Save
C06
Writes current Iop value in read nonvolatile memory using microprocessor
EF MO ADJUST
C07
Traverse (MO) adjustment
EF CD ADJUST
C08
Traverse (CD) adjustment
FBIAS ADJUST
C09
Focus bias adjustment
AG Set (MO)
C10
Auto gain output level adjustment (MO)
AG Set (CD)
C11
Auto gain output level adjustment (CD)
TEMP CHECK
C12
Temperature compensation offset check
LDPWR CHECK
C13
Laser power check
EF MO CHECK
C14
Traverse (MO) check
EF CD CHECK
C15
Traverse (CD) check
FBIAS CHECK
C16
Focus bias check
ScurveCHECK
C17
S-curve check
VERIFYMODE
C18
Nonvolatile memory check
DETRK CHECK
C19
Detrack check
0920 CHECK
C25
Most circumference check
Iop Read
C26
Iop data display
Iop Compare
C27
Comparison with initial Iop value written in nonvolatile memory
ADJ CLEAR
C28
Initialization of nonvolatile memory for adjustment values
INFORMATION
C31
Display of microprocessor version, etc.
CPLAY1MODE
C34
Continuous playback mode
CREC 1MODE
C35
Continuous recording mode
• For details of each adjustment mode, refer to "5. Electrical Adjustments".
For details of "Err Display", refer to "Self-Diagnosis Function" on page 2.
• If a different mode has been selected by mistake, press the MENU/NO "R" button to release that mode.
• Modes with ( ) in the Mark column are not used for servicing and therefore are not described in detail. If these modes are set
accidentally, press the MENU/NO "R" button to release the mode immediately.
26
Function
Changes parameters and modes
Proceeds onto the next step. Finalizes input
Returns to previous step. Stops operations
Details
Group
Mark
Check
Service

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents