Fig. 1 Reading the Test Mode Display
(During recording and stop)
RTs@@c##e
fluorescent indicator tube
@@ : Cause of retry
## : Number of retries
: Number of retry errors
**
Reading the Retry Cause Display
Higher Bits
Hexadecimal
8
4
2
Bit
b7
b6
b5
Binary
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
1
0
1
0
1
0
0
Reading the Display:
Convert the hexadecimal display into binary display. If more than two causes, they will be added.
Example
When 42 is displayed:
Higher bit: 4 = 0100 t b6
Lower bit : 2 = 0010 t b1
In this case, the retry cause is combined of "CLV unlock" and "ader5".
When A2 is displayed:
Higher bit: A = 1010 t b7 + b5
Lower bit : 2 = 0010 t b1
The retry cause in this case is combined of "Access fault", "IVR rec error", and "ader5".
**
Lower Bits
1
8
4
2
1
Hexadecimal
b4
b3
b2
b1
b0
0
0
0
0
1
01
0
0
0
1
0
02
0
0
1
0
0
04
0
1
0
0
0
08
1
0
0
0
0
10
0
0
0
0
0
20
0
0
0
0
0
40
0
0
0
0
0
80
Fig. 2 Reading the Test Mode Display
(During playback)
@@ ###
fluorescent indicator tube
@@ : Parts No. (name of area named on TOC)
## : Cluster
: Sector
**
$$ : Track mode (Track information such as
copyright information of each part)
Cause of Retry
shock
When track jump (shock) is detected
When ADER was counted more than five times
ader5
continuously
Discontinuous address
When ADIP address is not continuous
DIN unlock
When DIN unlock is detected
FCS incorrect
When not in focus
IVR rec erraor
When ABCD signal level exceeds the specified range
CLV unlock
When CLV is unlocked
Access fault
When access operation is not performed normally