NOTE:
The above installation would allow for two full depth drawers.
D U C T I N G TO T H E O U T S I D E
When ducting to the outside, 150mm solid rigid (220mm x 90mm flat channel) must be used and
the length should be kept to a minimum. We recommend no more than 3 meters with two 90
degree bends. If the flat channel duct is completely straight up to 5 meters is acceptable. Any more
than this will begin to effect the efficiency of the motor.
Avoid unnecessary bends, if bends are required use high efficiency corners (for example the Caple
950GL 150mm) to reduce the impact on performance.
R E C I R C U L AT I O N M O D E
The product can be recirculated by two methods:
» Plasma filtration
» Charcoal filter only
Instruction manual DD940BK
45
Please keep this instruction manual for future reference