7.0 OPTIONS

7.1 REMOTE START/STOP

The remote start/stop option allows the operator to
control the compressor from a remote mounted
start/stop station. This option may be factory
installed or a field installation kit is available. This
option is a plug-in module.
With the optional plug-in module installed, two
different switches can be wired to the Intellisys
remote start/stop. Refer to (Electrical Schematics 8.1
or 8.2 for wiring locations). The switches are
customer supplied and must be of the momentary
type. The stop switch contacts are normally closed
and start switch contacts are normally open.
7.2 REMOTE START-STOP AND POWER OUTAGE
RESTART OPTION
When remote start-stop and the Power Outage
Restart Option is desired, a combination field
installation kit that contains these features is
available. The option includes a plug-in module and
all of the hardware necessary.
The Power Outage Restart portion of the option is
for plants that have interruptions in their incoming
power supply to the compressor and must maintain
an uninterrupted supply of compressed air. When
turned on, the option allows the compressor to
automatically restart and load 10 seconds after
incoming power is restored after a power
interruption.

7.3 SEQUENCER CONTROL

Sequencer control capability can be added to the
®
Intellisys
System by utilizing a sequencer interface.
This option is available as a field installation kit.
This machine is remote
start and stop equipped.
May start or stop at
anytime.
Can cause severe injury or
®
for
death.
INGERSOLLrAND ®
WARNING
!
Disconnect power before
servicing.
Lock and tag out.
See Operators / Instruction
Manual.
45