Inspection Of Insulation On Thermocouple; Bending The Tip Of The Thermocouple - Intel 3210 Thermal/Mechanical Design Manual

Chipset
Table of Contents

Advertisement

Thermal Metrology
Figure 5-5.

Inspection of Insulation on Thermocouple

3. Measure the thermocouple resistance by holding both contacts on the connector on
one probe and the tip of thermocouple to the other probe of the DMM
(measurement should be about ~3.0 ohms for 36-gauge type T thermocouple).
4. Straighten the wire for about 38 mm [1.5 inch] from the bead.
5. Using the microscope and tweezers, bend the tip of the thermocouple at
approximately 10 degree angle by about 0.8 mm [.030 inch] from the tip. Refer to
Figure
Figure 5-6.

Bending the Tip of the Thermocouple

5.1.4.2
Thermocouple attach to the IHS
6. Clean groove and IHS with Isopropyl Alcohol (IPA) and a lint free cloth removing all
residues prior to thermocouple attachment.
7. Place the Thermocouple wire inside the groove and let the exposed wire extend
slightly over the end of groove. Refer to
Intel® 3210 and 3200 Chipset Thermal/Mechanical Design Guide
5-6.
Figure
5-7.
23