Electric Motor Drive; Electropneumatic Drive - JAUDT FSV 6110 Series Translation Of The Original Operating Instructions

Vario-slide valve
Table of Contents

Advertisement

Operating Instructions FSV 6110...
6.3

Electric motor drive

Work on the electrical system must only be carried out by qualified electricians.
Adhere to the "Reference Documentation" (Section 1.3) as well.
Check the electric motor drive. If noise emission develops, replace the ball bearing between the gear
unit and spindle.
Ensure that the electrical connection is not oxidised, damaged or leaking.
Check the limit switches with regard to their function and technical condition.
Replace the lubricant sensor.
Ensure the accident prevention guard is firmly fitted.
Adjust and replace the stuffing box gland (see Section 6.1).
6.4

Electropneumatic drive

Work on the electrical system must only be carried out by qualified electricians.
Check the pneumatic supply (pressure) and drain off if necessary.
Ensure that all solenoid valves are operating correctly.
Check the pneumatic system for leaks.
Check the limit switches (optional) with regard to their function and technical condition.
Ensure that the electrical connection is not oxidised, damaged or leaking.
Ensure that the accident prevention guard is firmly fitted.
See Section 6.1 for details of how to adjust and replace the stuffing box gland
The cylinder pipe of the electropneumatic drive is dependently of the nominal size of the vario slide valve
equipped with different diameters ØD.
Overview of the repair kit of the electrpneumatic drive make JAUDT:
ØD
A
80
M16x1,5
100
M16x1,5
125
M20x1,5
160
M30x1,5
200
M30x1,5
© BA6110.0002_EN_Rev11.docx
Order-number
of the repair kit:
601372
318610.0001
601108
601109
416610.0107
Page 11 of 19

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents