Airmatik Seal - JAUDT FSV 6110 Series Translation Of The Original Operating Instructions

Vario-slide valve
Table of Contents

Advertisement

Operating Instructions FSV 6110...
6.2

Airmatik seal

6.2.1 General:
The Airmatik seal (21) is positively located in a profile groove below the intake collar of
the housing (1). Pressure is applied by means of the pneumatic connection on the housing. It must not be
applied before the slide plate (5) is fully closed. This is achieved by means of the mechanical valve (23)
being actuated into the "Closed" position.
6.2.2 Seal changes:
Use a screwdriver to raise the Airmatik seal (21) at a particular place and then remove it from the profile
groove along with the seal join (22). Examine the profile groove and remove any dirt and furrows.
Lightly grease the O-ring of the valve connection of the new seal and carefully insert the new Airmatik seal
completely into the place of the valve connection. Introduce the Airmatik seal into the groove evenly on
both sides, starting from the valve connection.
The profile of the seal must engage completely in the profile groove. If this does not happen completely,
there is a risk that the seal will be forced out of the groove under pressure and will be damaged. Suitable
tools can be ordered from Jaudt.
Attention: Damage to materials!
Do not use any tools with sharp edges, e.g. small screwdrivers, when installing the new Air-
matik seal!
Make sure the valve connection is properly located!
© BA6110.0002_EN_Rev11.docx