DESCRIPTION OF OPERATION
The first version of the control board, 0486 205 886:
To enable the processor IC1, to select the correct software for the ESABFeed 30-4,
connection L01 must be linked to L02 and L03 to L04. For the ESABFeed 48-4 there is a link
only between L03 and L04.
Selection of motor type, circuit board 0486 205 886

13AP1:14 Gas purge

The circuit board has an input for gas purge, this is not used.

13AP1:15 Inching

The circuit board has an input for inching, this is not used.

13AP1:16 Remote control input

0740 800 144
- 30 -